Abstract—The structural system of wooden house by two-by-four method is widely adopted in any countries, and a various type of vibration control system for building structures has been developed on country with frequent earthquake. In this study, a vibration control device called “Scaling Frame” (SF) is suggested, and which is applied to wooden two-by-four method structures. This paper performs the experimental study to investigate the restoring force characteristics of two-by-four with SF device installed. The seismic resistant performance is estimated experimentally, and also the applicability and effectiveness are discussing.
منابع مشابه
Performance-Based Plastic Design of Moment Frame-Steel Plate Shear Wall as a Dual System
Steel Plate Shear Wall (SPSW) is an emerging seismic load-resistant system that, compared to other systems, enjoys the advantages of stable ductile behavior, fewer detailing requirements, rapid constructability, and economy. American seismic provisions decree that a SPSW should be designed as a moment frame with a web infill plate. Specifically, in case of buildings taller than 160 ft, it decre...
متن کاملFree Vibration Analysis of a Sloping-frame: Closed-form Solution versus Finite Element Solution and Modification of the Characteristic Matrices (TECHNICAL NOTE)
This article deals with the free vibration analysis and determination of the seismic parameters of a sloping-frame which consists of three members; a horizontal, a vertical, and an inclined member. The both ends of the frame are clamped, and the members are rigidly connected at joint points. The individual members of the frame are assumed to be governed by the transverse vibration theory of an ...
متن کاملFree Vibration of a Generalized Plane Frame
This article deals with the free in-plane vibration analysis of a frame with four arbitrary inclined members by differential transform method. Based on four differential equations and sixteen boundary and compatibility conditions, the related structural eigenvalue problem will be analytically formulated. The frequency parameters and mode shapes of the frame will be calculated for various values...
متن کاملActive vibration control of smart building frames by feedback controllers
In this paper the active vibration control of a four-story shear frame instrumented with piezoelectric actuators is presented. The piezoelectric actuators are hosted on the columns in two manners and the produced controlling forces by actuators are considered in the equation of motion. The smart structure modeling and control design is carried out using MATLAB software in state space form. Subs...
متن کاملStudy and Comparison of Seismic Behaviour of Isolator-Damper Hybrid Control System with Conventional Structural Systems
In this paper, in addition to introduce a hybrid structural system contained local isolators and dampers, its behavior and functional capabilities were studied on a conventional structure. For this purpose, an RC frame building with six-story was designed based on valid codes and then, in four cases based on the number of spans, it was split into two separate adjacent frames. Base isolation was...