Biocompatibility evaluation of a new bioresorbable pin for membrane fixation.

نویسندگان

  • Tania Mary Cestari
  • Rodrigo Cardoso de Oliveira
  • Jefferson Tomio Sanada
  • Gustavo Pompermaier Garlet
  • Rumio Taga
  • José Mauro Granjeiro
چکیده

The aim of this study was to morphometrically analyze the tissue response to a customized pin obtained from devitalized bovine cortical bone (DBCB-pin) implanted in the subcutaneous tissue of rats, as well as to assess its microstructural aspect by scanning electron microscopy (SEM). The pins were implanted in the subcutaneous tissue of 20 rats, which were killed at 7, 14, 28 and 60 days (5 rats/period) after implantation. In the subcutaneous tissue, DBCB-pin promoted the formation of a fibrous capsule. At 7 days, capsule showed thickness of 70 ± 3.2 µm with higher density of newly formed capillaries and smaller density of collagen fibers. Between 14 and 60 days, more organized fibrous capsule exhibited smaller thickness (53 ± 5.5 µm) with higher density of fibroblasts and collagen fibers. In this period, a small and slow bioresorption of the DBCB-pin by macrophages and rare multinucleated giant cells without tissue damage was observed. The thickness of DBCB-pin resorbed was in mean only of 9.3 µm. During all experimental periods not occurred presence of immune reaction cells as lymphocytes and plasma cells. It was concluded that the pin derived from cortical bovine bone was well tolerated by subcutaneous tissue of rats and slowly resorbed could be an alternative material for membrane fixation in the guided tissue regeneration procedures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of close reduction and percutaneous pin fixation as treatments for distal metaphyseal radius fractures

Background: Distal radius fractures are one of the most common fractures of skeletal system and because of the aging of population, its incidence is rising. The aim of the present research was to evaluate the close reduction and percutaneous pin fixation as a treatment option. Material and methods: 44 patients who were type 2 according to universal classification or type 2 or 3 according to Ol...

متن کامل

مقایسه نتایج جااندازی بسته با پین‌گذاری از راه پوست و جااندازی باز با فیکساسیون داخلی در شکستگی سوپراکندیلار بازو در بچه‌ها

ABSTRACT Type III supracondylar fractures of humerus is a common fracture of children with high rate of complications. There is many contraversies about its treatment. Closed reduction and percutaneous pin fixation and also open reduction and internal fixation are two routine surgical methods for this fracture each with own risk and benefits. This is a retrospective study on 49 patient...

متن کامل

Treatment of Open Tibial Fractures: Convert-ing or Continuing External Fixation?

Background: The treatment of open tibial fractures is still an orthopaedic challenge and full of complications. In many cases the use of external fixator that has been known as a non-union machine is obligatory with a high incidence of pin track infection and other complications. The aim of this study was to compare the use of external fixation as a definite method for treatment of open tibial ...

متن کامل

Perspectives on resorbable osteosynthesis materials in craniomaxillofacial surgery.

Since introduction to the clinics in the 1990s, resorbable osteosynthesis systems have undergone extensive improvements in order to establish their use as a standard treatment, especially in craniomaxillofacial surgery. However, the development of osteosynthesis systems made of poly(α-hydroxy acid) polymers has been hindered by the lack of information on the mechanical properties and biocompati...

متن کامل

Advances in Polysulfone-Based Membranes for Hemodialysis

The polysulfone-based membrane has been used in hemodialysis (HD) and it is continuously developed to maintain its sustainability on the subject of biocompatibility. During the polysulfone-based membrane development, several parameters should be considered to improve the membrane performances, such as excellent biocompatibility, appropriate ultrafiltration rate, and effective clearance of the t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brazilian dental journal

دوره 21 6  شماره 

صفحات  -

تاریخ انتشار 2010