Head to head comparison of 2D vs real time 3D dipyridamole stress echocardiography

نویسندگان

  • Silvia Varnero
  • Patricia Santagata
  • Lorenza Pratali
  • Massimiliano Basso
  • Alfredo Gandolfo
  • Paolo Bellotti
چکیده

Real-time three-dimensional (RT-3D) echocardiography has entered the clinical practice but true incremental value over standard two-dimensional echocardiography (2D) remains uncertain when applied to stress echo. The aim of the present study is to establish the additional value of RT-3D stress echo over standard 2D stress echocardiography. We evaluated 23 consecutive patients (age = 65 +/- 10 years, 16 men) referred for dipyridamole stress echocardiography with Sonos 7500 (Philips Medical Systems, Palo, Alto, CA) equipped with a phased - array 1.6-2.5 MHz probe with second harmonic capability for 2D imaging and a 2-4 MHz matrix-phased array transducer producing 60 x 70 volumetric pyramidal data containing the entire left ventricle for RT-3D imaging. In all patients, images were digitally stored in 2D and 3D for baseline and peak stress with a delay between acquisitions of less than 60 seconds. Wall motion analysis was interpreted on-line for 2D and off-line for RT-3D by joint reading of two expert stress ecocardiographist. Segmental image quality was scored from 1 = excellent to 5 = uninterpretable. Interpretable images were obtained in all patients. Acquisition time for 2D images was 67 +/- 21 sec vs 40 +/- 22 sec for RT-3D (p = 0.5). Wall motion analysis time was 2.8 +/- 0.5 min for 2D and 13 +/- 7 min for 3D (p = 0.0001). Segmental image quality score was 1.4 +/- 0.5 for 2D and 2.6 +/- 0.7 for 3D (p = 0.0001). Positive test results was found in 5/23 patients. 2D and RT-3D were in agreement in 3 out of these 5 positive exams. Overall stress result (positive vs negative) concordance was 91% (Kappa = 0.80) between 2D and RT-3D. During dipyridamole stress echocardiography RT-3D imaging is highly feasible and shows a high concordance rate with standard 2D stress echo. 2D images take longer time to acquire and RT-3D is more time-consuming to analyze. At present, there is no clear clinical advantage justifying routine RT-3D stress echocardiography use.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The diagnostic accuracy of pharmacological stress echocardiography for the assessment of coronary artery disease: a meta-analysis

BACKGROUND Recent American Heart Association/American College of Cardiology guidelines state that "dobutamine stress echo has substantially higher sensitivity than vasodilator stress echo for detection of coronary artery stenosis" while the European Society of Cardiology guidelines and the European Association of Echocardiography recommendations conclude that "the two tests have very similar ap...

متن کامل

Quantification of functional mitral regurgitation by real-time 3D echocardiography: comparison with 3D velocity-encoded cardiac magnetic resonance.

OBJECTIVES The aim of this study was to evaluate feasibility and accuracy of real-time 3-dimensional (3D) echocardiography for quantification of mitral regurgitation (MR), in a head-to-head comparison with velocity-encoded cardiac magnetic resonance (VE-CMR). BACKGROUND Accurate grading of MR severity is crucial for appropriate patient management but remains challenging. VE-CMR with 3D three-...

متن کامل

Multiplane two-dimensional versus real time three-dimensional transesophageal echocardiography in ischemic mitral regurgitation.

OBJECTIVES Intraoperative three-dimensional (3D) transesophageal echocardiography (TEE) has been suggested to be a valuable technique for the evaluation of the mechanisms of ischemic mitral regurgitation (IMR). Studies comparing multiplane two-dimensional (2D) with 3D TEE reconstruction of the mitral valve using the new mitral valve quantification (MVQ) software are lacking. We undertook a pros...

متن کامل

Comparison of exercise, dobutamine-atropine and dipyridamole-atropine stress echocardiography in detecting coronary artery disease

BACKGROUND Dipyridamole and dobutamine stress echocardiography testing are most widely utilized, but their sensitivity remained suboptimal in comparison to routine exercise stress echocardiography. The aim of our study is to compare, head-to-head, exercise, dobutamine and dipyridamole stress echocardiography tests, performed with state-of-the-art protocols in a large scale prospective group of ...

متن کامل

Comparison of real-time tri-plane and conventional 2D dobutamine stress echocardiography for the assessment of coronary artery disease.

AIMS Although dobutamine stress echocardiography (DSE) is an accepted tool for the diagnosis of coronary artery disease (CAD), it requires subsequent image acquisitions of the left ventricle (LV) in order to visualize all segments. This makes the procedure relatively time-consuming and might limit its accuracy. With the introduction of matrix array transducers, the real-time simultaneous acquis...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cardiovascular Ultrasound

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2008