Optimal Signal Quality Index for Photoplethysmogram Signals
نویسنده
چکیده
A photoplethysmogram (PPG) is a noninvasive circulatory signal related to the pulsatile volume of blood in tissue and is typically collected by pulse oximeters. PPG signals collected via mobile devices are prone to artifacts that negatively impact measurement accuracy, which can lead to a significant number of misleading diagnoses. Given the rapidly increased use of mobile devices to collect PPG signals, developing an optimal signal quality index (SQI) is essential to classify the signal quality from these devices. Eight SQIs were developed and tested based on: perfusion, kurtosis, skewness, relative power, non-stationarity, zero crossing, entropy, and the matching of systolic wave detectors. Two independent annotators annotated all PPG data (106 recordings, 60 s each) and a third expert conducted the adjudication of differences. The independent annotators labeled each PPG signal with one of the following labels: excellent, acceptable or unfit for diagnosis. All indices were compared using Mahalanobis distance, linear discriminant analysis, quadratic discriminant analysis, and support vector machine with leave-one-out cross-validation. The skewness index outperformed the other seven indices in differentiating between excellent PPG and acceptable, acceptable combined with unfit, and unfit recordings, with overall F 1 scores of 86.0%, 87.2%, and 79.1%, respectively.
منابع مشابه
Quantification the Effect of Ageing on Characteristics of the Photoplethysmogram Using an Optimized Windkessel Model
Background: With increasing age, some changes appeared in specifications of vessels which including dimensions and elasticity in their. The changes in parameters such as resistance, inertance and compliance vessels appear and eventually changes in the environmental pulse releases are in circulation. These changes clearly appear in specification of photoplethysmogram particularly in the size and...
متن کاملa and b waves detection in acceleration photoplethysmogram
An efficient and robust method based on two moving average filters followed by a dynamic event duration threshold has been developed to detect a and b waves in the acceleration photoplethysmogram signals. The detection of a and b waves is affected by the quality of the photoplethysmogram recordings, especially for the heat stressed collection. The developed a method detects a and b waves in Arr...
متن کاملExtraction of respiratory signals from the electrocardiogram and photoplethysmogram: technical and physiological determinants.
OBJECTIVE Breathing rate (BR) can be estimated by extracting respiratory signals from the electrocardiogram (ECG) or photoplethysmogram (PPG). The extracted respiratory signals may be influenced by several technical and physiological factors. In this study, our aim was to determine how technical and physiological factors influence the quality of respiratory signals. APPROACH Using a variety o...
متن کاملAssessment of Photoplethysmography Method in Extraction of Hemoglobin Concentration
Background: The importance of continuous monitoring along with rapid and accurate notification of changes in blood components such as hemoglobin concentration, especially in acute situations, encourages researchers to use non-invasive methods for measuring.Objective: This study was aimed to investigate the correlation between hemoglobin concentration and photoplethysmogram (PPG) and the p...
متن کاملOn Time Domain Analysis of Photoplethysmogram Signals for Monitoring Heat Stress
There are a limited number of studies on heat stress dynamics during exercise using the photoplethysmogram (PPG) and its second derivative (APG). However, we investigate the most suitable index from short PPG signal recordings for heat stress assessment. The APG waveform consists of a, b, c and d waves in systole and an e wave in diastole. Our preliminary results indicate that the use of the en...
متن کامل