The capture envelope of a flanged circular hood in cross drafts.
نویسندگان
چکیده
The flow patterns of an exterior circular hood subject to the influence of various uniform cross drafts were experimentally studied in an apparatus consisting of hood-model/wind-tunnel assembly. A two-component laser Doppler anemometer was employed to measure the velocity field on the symmetry plane. The streamline patterns were obtained from the measured velocity data. The cross draft caused a characteristic envelope similar to a half Rankine body-of-revolution to form in the flow field. The boundary of the envelope is described by a dividing streamline. All streamlines within the envelope lead to the opening; those outside the envelope evolve to the downstream area. The normalized geometry of the capture envelope is theoretically justified and correlated by modifying the potential theory of point-sink-plus-rectilinear-flow. The domain and shape of the envelope enclosing the hood opening are determined primarily by the velocity ratio between the cross draft and hood suction. The correlated formula is applicable to design the hood parameters, including the sizes of opening and flange as well as the location of contaminant sources.
منابع مشابه
Effects of flange size on dividing streamlines of exterior hoods in cross drafts.
Effects of flange size on the flow patterns of an exterior circular hood subject to the influence of various uniform cross drafts were studied in an apparatus consisting of hood-model/wind-tunnel assembly. The cross draft to suction velocity ratio covered the range from 0.056 to 0.792. The flange width to hood diameter ratio spanned from 1.2 to 3.0. The hood equipped without flange was also pro...
متن کاملEvaluation of engineering controls for the mixing of flavorings containing diacetyl and other volatile ingredients.
Exposures to diacetyl, a primary ingredient of butter flavoring, have been shown to cause respiratory disease among workers who mix flavorings. This study focused on evaluating ventilation controls designed to reduce emissions from the flavor mixing tanks, the major source of diacetyl in the plants. Five exhaust hood configurations were evaluated in the laboratory: standard hinged lid-opened, s...
متن کاملOptimizing Appliance Position and Hood Configuration
1 “Hot air rises!” This introductory sentence to Design Guide 1 states the obvious. But why does it sometimes rise and stay within the hood envelope and other times fill the kitchen with smoke, grease, and heat? Recent research sponsored by the American Society of Heating, Refrigeration, and Air-conditioning Engineers (ASHRAE) provided intriguing insights into this question. In addition to the ...
متن کاملطراحی و ارزیابی عملکرد سامانۀ تهویۀ مکشی موضعی بر روی مشعل جوشکاری
Background and aims: The welders' health threat due to exposure to welding fume is an important issue, so effective exhaust of fumes are needful for to be assured from the workers safety in exposured to such proccess. In this study, was evaluated prototype operation of local exhaust ventilation on-gun in bench scale. Methods: duct velocity Average was determined by using traverse points meth...
متن کاملA hybrid finite element approach to modeling sound radiation from circular and rectangular ducts.
A numerical model based on a hybrid finite element method is developed that seeks to join sound pressure fields in interior and exterior regions. The hybrid method is applied to the analysis of sound radiation from open pipes, or ducts, and uses mode matching to couple a finite element discretization of the region surrounding the open end of the duct to wave based modal expansions for adjoining...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AIHAJ : a journal for the science of occupational and environmental health and safety
دوره 62 2 شماره
صفحات -
تاریخ انتشار 2001