Comparison of the glidescope, CMAC, storz DCI with the Macintosh laryngoscope during simulated difficult laryngoscopy: a manikin study
نویسندگان
چکیده
UNLABELLED BACKGROUND Videolaryngoscopy presents a new approach for the management of the difficult and rescue airway. There is little available evidence to compare the performance features of these devices in true difficult laryngoscopy. METHODS A prospective randomized crossover study was performed comparing the performance features of the Macintosh Laryngoscope, Glidescope, Storz CMAC and Storz DCI videolaryngoscope. Thirty anesthesia providers attempted intubation with each of the 4 laryngoscopes in a high fidelity difficult laryngoscopy manikin. The time to successful intubation (TTSI) was recorded for each device, along with failure rate, and the best view of the glottis obtained. RESULTS Use of the Glidescope, CMAC and Storz videolaryngoscopes improved the view of the glottis compared with use of the Macintosh blade (GEE, p = 0.000, p = 0.002, p = 0.000 respectively). Use of the CMAC resulted in an improved view compared with use of the Storz VL (Fishers, p = 0.05). Use of the Glidescope or Storz videolaryngoscope blade resulted in a longer TTSI compared with either the Macintosh (GLM, p = 0.000, p = 0.029 respectively) or CMAC blades (GLM, p = 0.000, p = 0.033 respectively). CONCLUSIONS Unsurprisingly, when used in a simulated difficult laryngoscopy, all the videolaryngoscopes resulted in a better view of the glottis than the Macintosh blade. However, interestingly the CMAC was found to provide a better laryngoscopic view that the Storz DCI Videolaryngoscope. Additionally, use of either the Glidescope or Storz DCI Videolaryngoscope resulted in a prolonged time to successful intubation compared with use of the CMAC or Macintosh blade. The use of the CMAC during manikin simulated difficult laryngoscopy combined the efficacy of attainment of laryngoscopic view with the expediency of successful intubation. Use of the Macintosh blade combined expedience with success, despite a limited laryngoscopic view. The limitations of a manikin model of difficult laryngoscopy limits the conclusions for extrapolation into clinical practice.
منابع مشابه
Comparison of the Glidescope® and Pentax AWS® laryngoscopes to the Macintosh laryngoscope for use by Advanced Paramedics in easy and simulated difficult intubation
BACKGROUND Intubation of the trachea in the pre-hospital setting may be lifesaving in severely ill and injured patients. However, tracheal intubation is frequently difficult to perform in this challenging environment, is associated with a lower success rate, and failed tracheal intubation constitutes an important cause of morbidity. Novel indirect laryngoscopes, such as the Glidescope and the A...
متن کاملComparison of Indirect Video Laryngoscopes in Children Younger than Two Years of Age: a Randomized Trainee Evaluation Study.
BACKGROUND Gaining proficiency with various airway management tools is an important goal for anesthesiology training. Indirect video laryngoscopes facilitate tracheal intubation in adults, but it is not clear whether these findings translate to children. This study evaluates the total time to successful intubation when performed by anesthesiology trainees using GlideScope Cobalt® video laryngos...
متن کاملComparison of different intubation techniques performed inside a moving ambulance: a manikin study.
OBJECTIVE. Airway management and endotracheal intubation may be required urgently when a patient deteriorates in an ambulance or aircraft during interhospital transfer or in a prehospital setting. The objectives of this study were: (1) to compare the effectiveness of conventional intubation by Macintosh laryngoscope in a moving ambulance versus that in a static ambulance; and (2) to compare the...
متن کاملComparison of the Incidence of Sore Throat and Hemodynamic Changes in Airway Management by Macintosh, Glideoscope Laryngoscope and Laryngeal Mask Airway Techniques: Randomized Controlled Trial
Background: Studies have shown that postoperative sore throat is the most common complication of tracheal intubation, However, the actual incidence and extent of it are not well documented. Objective: The aim of this study was to evaluate and compare the incidence of sore throat and hemodynamic Changes in Macintosh, Glidescope Laryngoscope and laryngeal mask airway techniques in elective surg...
متن کاملمقایسه میزان موفقیت لوله گذاری تراشه بعد از آموزش با دو روش گلایدسکوپ و لارنگوسکوپ
Background: Tracheal intubation is one of the most essential skills employed by all healthcare providers, nevertheless novice intubators turn out to be less successful when they initially perform the intubation. Video- laryngoscopes (GlideScopes) are novel instruments able to increase the success rate of tracheal intubation training. The aim of this study was to compare the success rate of trac...
متن کامل