The purpose of this study was to evaluate LC Bead LUMI™ (40-90µm and 70-150µm) in order to determine if their increased resistance to compression influences microsphere penetration and distribution compared to more compressible commercial microspheres. LC Bead LUMI™ 40-90µm and 70-150µm, LC BeadM1® 70-150µm, Embozene™ 40µm and Embozene™ 100µm size and distributions were measured using optical microscopy. Penetration in vitro was evaluated using an established 'plate model', consisting of a calibrated tapered gap between a glass plate and plastic housing to allow visual observation of microsphere penetration depth. Behaviour in vivo was assessed using a rabbit renal embolization model with histopathologic confirmation of vessel penetration depth. Penetration behaviour in vitro was reproducible and commensurate with the measured microsphere size, the smaller the microsphere the deeper the penetration. Comparison of the microsphere diameter measured on the 2D plate model versus the corresponding average microsphere size measured by histopathology in the kidney showed no significant differences (p = > 0.05 Mann-Whitney, demonstrating good in vitro - in vivo predictive capabilities of the plate model) confirming predictable performance for LC Bead LUMI™ (40-90µm and 70-150µm) based on microsphere size, their increased rigidity having no bearing on their depth of penetration and distribution. An assessment of a LC Bead LUMI™ (40-90µm and 70-150µm) has shown that despite having greater resistance to compression, these microspheres behave in a predictable manner within in vitro and in vivo models comparable with more compressible microspheres of similar sizes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Acetone sensing properties of hierarchical WO3 core-shell microspheres in comparison with commercial nanoparticles

In this work, hierarchical WO3 core-shell microspheres were synthesized via a facile template-free precipitation method. Gas sensing properties of the synthesized powder to acetone and some other volatile organic compounds were comparatively investigated with commercial WO3 nanoparticles. The synthesized and commercial powders were characterized by X-ray diffraction, scanning electron microscop...

متن کامل

Acetone sensing properties of hierarchical WO3 core-shell microspheres in comparison with commercial nanoparticles

In this work, hierarchical WO3 core-shell microspheres were synthesized via a facile template-free precipitation method. Gas sensing properties of the synthesized powder to acetone and some other volatile organic compounds were comparatively investigated with commercial WO3 nanoparticles. The synthesized and commercial powders were characterized by X-ray diffraction, scanning electron microscop...

متن کامل

Humoral Immune Response Induced by PLGA Micro Particle Coupled Newcastle Disease Virus Vaccine in Chickens

This experiment was conducted for evaluating the humoral immune responses induced by Poly Lactide-co-Glycolide Acid (PLGA) microspheres coupled inactivated Newcastle Disease Virus (NDV) vaccine in comparison to an ‘in-house’ prepared inactivated and a live commercial vaccine. PLG microparticles containing inactivated NDV were prepared by a double emulsion technique based on solvent evaporation ...

متن کامل

Encapsulation of Naja –Naja Oxiana Snake venom into Poly (lactide-co-glycolide) microspheres

One small-scale double emulsion technique for incorporation of Naja- Naja oxiana venom into Poly (lactide-co-glycolide) (PLGA) microspheres were developed and optimized. The effects of high speed homogenization on the double emulsion stability, microsphere size, entrapment efficiency and In vitro release of venom were studied. A stable double emulsion was verified by homogenization method. Slow...

متن کامل

Alginate Microsphere as a Delivery System and Adjuvant for Autoclaved Leishmania major and Quillaja Saponin: Preparation and Characterization

     The goal of this study was to prepare and characterize alginate microspheres as an antigen delivery system and adjuvant for immunization against leishmaniasis. Microspheres encapsulated with autoclaved Leishmania major (ALM) and Quillaja saponin (QS) were prepared by an emulsification technique and characterized for size, encapsulation efficiency and release profile of encapsulate...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the mechanical behavior of biomedical materials

دوره 78  شماره 

صفحات  -

تاریخ انتشار 2018