This communication describes and discusses the results obtained in studying central and )eripheral arterial pressure pulses in man by means of retrograde aortic catheterization. The pressure pulse transformation and pulse transmission in the aorticobrachial system are presented and compared with comparable tracings reported in the dog. Several normal subjects and patients with hypertension, aortic regurgitation and coarctation of the aorta were studied. The genesis of the central pulse contour in aortic regurgitation is reconsidered. The changes in central pulse pressure, produced by the Valsalva-like maneuver, and ventricular premature systoles have been investigated, especially in their relationship to cycle length, end-diastolic volume and peripheral resistance. The technic of obtaining pulse pressure recordings by retrograde aortic catheterization is recommended for determining the location, size and dynamic significance of coarctation of the aorta. As an additional study, aortic densograms and border electrokymograms from the aortic arch and left ventricular border were correlated with simultaneously recorded central aortic pres-
منابع مشابه
A Preliminary Report
In order to define more precisely meaningful points on ventricular and great vessel electrokymograms, intraluminal and intracavitary pressures have been simultaneously recorded. Electrokymograms of the superior vena cava and the pulmonary artery show remarkable constancy of time relationships with simultaneously recorded intraluminal pressure curves. The ventricular electrokymogram is more diff...
متن کاملCorrelation of simultaneously recorded electrokymograms and pressure pulses of human heart and great vessels; a preliminary report.
In order to define more precisely meaningful points on ventricular and great vessel electrokymo-grams, intraluminal and intracavitary pressures have been simultaneously recorded. Electro-kymograms of the superior vena cava and the pulmonary artery show remarkable constancy of time relationships with simultaneously recorded intraluminal pressure curves. The ventricular electrokymogram is more di...
متن کاملFunctional cortical source imaging from simultaneously recorded ERP and fMRI.
Feasibility of continuously and simultaneously recording visual evoked potentials (VEPs) with fMRI was assessed by quantitatively comparing cortical source images by means of receiver operating characteristic (ROC) curve analysis. The averaged EEG source images coincided well with simultaneously acquired fMRI activations. Strong correlation was found between the cortical source images of VEPs r...
متن کاملCorrelation of fluctuations in simultaneously recorded VEP and BOLD fMRI
Introduction Studies comparing visual evoked potentials (VEPs) and BOLD signals have found a positive correlation between the VEP amplitude and the magnitude and extent of the BOLD signal [1, 2], but some VEP components are better related to the BOLD signal than others. The strongest spatial correlation have been found between the source location of the N1 peak* and the location of the BOLD sig...
متن کاملAssessment of Photoplethysmography Method in Extraction of Hemoglobin Concentration
Background: The importance of continuous monitoring along with rapid and accurate notification of changes in blood components such as hemoglobin concentration, especially in acute situations, encourages researchers to use non-invasive methods for measuring.Objective: This study was aimed to investigate the correlation between hemoglobin concentration and photoplethysmogram (PPG) and the p...
متن کامل