Noise correction for the exact determination of apparent diffusion coefficients at low SNR.
نویسندگان
چکیده
Noise in MR image data increases the mean signal intensity of image regions due to the usually performed magnitude reconstruction. Diffusion-weighted imaging (DWI) is especially affected by high noise levels for several reasons, and a decreasing SNR at increasing diffusion weighting causes systematic errors when calculating apparent diffusion coefficients (ADCs). Two different methods are presented to correct biased signal intensities due to the presence of complex noise: 1) with Gaussian intensity distribution, and 2) with arbitrary intensity distribution. The performance of the correction schemes is demonstrated by numerical simulations and DWI measurements on two different MR systems with different noise characteristics. These experiments show that noise significantly influences the determination of ADCs. Applying the proposed correction schemes reduced the bias of the determined ADC to less than 10% of the bias without correction. Magn Reson Med 45:448-453, 2001.
منابع مشابه
روشی نوین در کاهش نوفه رایسین از مقدار بزرگی سیگنال دیفیوژن در تصویربرداری تشدید مغناطیسی (MRI)
The true MR signal intensity extracted from noisy MR magnitude images is biased with the Rician noise caused by noise rectification in the magnitude calculation for low intensity pixels. This noise is more problematic when a quantitative analysis is performed based on the magnitude images with low SNR(<3.0). In such cases, the received signal for both the real and imaginary components will fluc...
متن کاملInfluence of Noise Correction on Intra- and Inter-Subject Variability of Quantitative Metrics in Diffusion Kurtosis Imaging
Diffusion kurtosis imaging (DKI) is a promising extension of diffusion tensor imaging, giving new insights into the white matter microstructure and providing new biomarkers. Given the rapidly increasing number of studies, DKI has a potential to establish itself as a valuable tool in brain diagnostics. However, to become a routine procedure, DKI still needs to be improved in terms of robustness,...
متن کاملParameter estimation using macroscopic diffusion MRI signal models.
Macroscopic models of the diffusion MRI (dMRI) signal can be helpful to understanding the relationship between the tissue microstructure and the dMRI signal. We study the least squares problem associated with estimating tissue parameters such as the cellular volume fraction, the residence times and the effective diffusion coefficients using a recently developed macroscopic model of the dMRI sig...
متن کاملCapacity Bounds and High-SNR Capacity of the Additive Exponential Noise Channel With Additive Exponential Interference
Communication in the presence of a priori known interference at the encoder has gained great interest because of its many practical applications. In this paper, additive exponential noise channel with additive exponential interference (AENC-AEI) known non-causally at the transmitter is introduced as a new variant of such communication scenarios. First, it is shown that the additive Gaussian ch...
متن کاملجهت یابی چند گوینده با استفاده از روش WCSSDOA
In this paper we propose the spatial sparsity based WCSSDOA method for multi speakers' Direction of arrival estimation. In the proposed method the sparse modeling is done based on the sensor signals' correlation matrix, which leads to low computational complexity. In this method the SVD decomposition of the noise covariance matrix is proposed to reach the free noise sparse model, which leads to...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Magnetic resonance in medicine
دوره 45 3 شماره
صفحات -
تاریخ انتشار 2001