Small-incision Descemet stripping automated endothelial keratoplasty: a comparison of small-incision tissue injector and forceps techniques.
نویسندگان
چکیده
PURPOSE To describe a novel, small-incision, no-fold Descemet stripping automated endothelial keratoplasty (DSAEK) graft injector and to compare complications, visual acuity, and endothelial cell loss with a forceps technique. METHODS An Institutional Review Board-approved, interventional, nonrandomized, consecutive case series analysis of 175 eyes undergoing DSAEK for Fuchs dystrophy and bullous keratopathy. The injector arm is prospective, and the forceps arm is retrospective. Seventy grafts were performed with a DSAEK graft injector, and 105 grafts were performed using a small-incision forceps technique. Preoperative and postoperative visual acuities at 3 and 6 months, 6-month endothelial cell counts, and complications, including graft dislocation, failure, and rejection, were recorded. Fifty-seven of 232 eyes met exclusion criteria for previous incisional corneal or glaucoma surgery. RESULTS There were 4 eyes (5.7%) in the injector group and 29 eyes (27.6%) in the forceps group that required a re-bubble procedure because of graft detachment. One graft (1.4%) failed in the injector group and 7 grafts (6.5%) failed in the forceps group. Excluding eyes with other ocular comorbidities (43), in the injector group 74% were 20/40 or better at 6 months and 100% were 20/60 or better. In the forceps group, 72% were 20/40 or better at 6 months and 98% were 20/60 or better. Six-month postoperative endothelial cell counts were available for 84 (46 injector and 38 forceps) eyes, with an average cell loss of 28.3% in the injector group and 44.1% in the forceps group. CONCLUSIONS DSAEK is an effective treatment of endothelial dysfunction. Surgical technique is important to limit endothelial cell loss and prevent complications, such as graft dislocation. The injector device has several advantages over the trifold forceps technique, including decreased endothelial cell loss, graft dislocation rate, and graft failure rate, and it reduces the DSAEK learning curve. DSAEK graft injectors likely will have a role in the future of endothelial keratoplasty.
منابع مشابه
Descemet stripping automated endothelial keratoplasty in phakic eyes: incision modification reducing cataract formation.
AIM To evaluate the efficacy of a technical modification to reduce the incidence of traumatic cataract induced by Descemet stripping automated endothelial keratoplasty (DSAEK) performed in phakic eyes. METHODS A retrospective cohort study. The records of all patients with a clear crystalline lens and endothelial failure that underwent modified DSAEK at our insitution were reviewed. In this mo...
متن کاملIn vitro evaluation of endothelial cell loss using the Neusidl Corneal Inserter.
PURPOSE To determine the immediate endothelial cell loss (ECL) resulting from insertion of a precut donor button using the Neusidl Corneal Inserter (NCI) and compare it with the previously published ECL resulting from insertion of a folded donor button using non-coapting forceps. METHODS Ten corneas were precut for Descemet stripping automated endothelial keratoplasty and trephinated to a dia...
متن کاملDescemet stripping automated endothelial keratoplasty
Endothelial keratoplasty is at present the gold standard for surgical treatment of corneal endothelial pathologies not associated with significant corneal scar. Tremendous progress has been made in recent years in improving the technology of endothelial keratoplasty techniques, such as descemet stripping automated endothelial keratoplasty (DSAEK) and descemet membrane endothelial keratoplasty. ...
متن کاملExperience and 12-month results of descemet-stripping endothelial keratoplasty (DSEK) with a small-incision technique.
PURPOSE To report our clinical experience and 12-month results of small-incision Descemet-stripping endothelial keratoplasty (DSEK). METHODS Prospective study of 11 eyes of 9 patients who had DSEK. The DSEK technique consisted of stripping the Descemet membrane and endothelium from the recipient cornea. The donor button was prepared by manual dissection and inserted through a 5-mm incision. A...
متن کاملEffects of a Novel Push-through Technique Using the Implantable Collamer Lens Injector System for Graft Delivery during Endothelial Keratoplasty
PURPOSE To investigate effects of a new push-through insertion method for donor lenticules using an injector system on endothelial viability ex vivo and in a clinical case series of endothelial keratoplasty. METHODS An ex vivo delivery model was used with porcine corneoscleral rims. We compared the endothelial viability in a new push-through insertion method using the Visian Implantable Colla...