Effect of repetitive pecking at working length for glide path preparation using G-file
نویسندگان
چکیده
OBJECTIVES Glide path preparation is recommended to reduce torsional failure of nickel-titanium (NiTi) rotary instruments and to prevent root canal transportation. This study evaluated whether the repetitive insertions of G-files to the working length maintain the apical size as well as provide sufficient lumen as a glide path for subsequent instrumentation. MATERIALS AND METHODS The G-file system (Micro-Mega) composed of G1 and G2 files for glide path preparation was used with the J-shaped, simulated resin canals. After inserting a G1 file twice, a G2 file was inserted to the working length 1, 4, 7, or 10 times for four each experimental group, respectively (n = 10). Then the canals were cleaned by copious irrigation, and lubricated with a separating gel medium. Canal replicas were made using silicone impression material, and the diameter of the replicas was measured at working length (D0) and 1 mm level (D1) under a scanning electron microscope. Data was analysed by one-way ANOVA and post-hoc tests (p = 0.05). RESULTS The diameter at D0 level did not show any significant difference between the 1, 2, 4, and 10 times of repetitive pecking insertions of G2 files at working length. However, 10 times of pecking motion with G2 file resulted in significantly larger canal diameter at D1 (p < 0.05). CONCLUSIONS Under the limitations of this study, the repetitive insertion of a G2 file up to 10 times at working length created an adequate lumen for subsequent apical shaping with other rotary files bigger than International Organization for Standardization (ISO) size 20, without apical transportation at D0 level.
منابع مشابه
Energy consumption of ProTaper Next X1 after glide path with PathFiles and ProGlider.
INTRODUCTION Instrument failure caused by excessive torsional stress can be controlled by creating a manual or mechanical glide path. The ProGlider single-file system (Dentsply Maillefer, Ballaigues, Switzerland) was recently introduced to perform a mechanical glide path. This study was designed to compare the effect of a glide path performed with PathFiles (Dentsply Maillefer) and ProGlider on...
متن کاملInfluence of glide path on the screw-in effect and torque of nickel-titanium rotary files in simulated resin root canals
OBJECTIVES The purpose of this study was to investigate the screw-in effect and torque generation depending on the size of glide path during root canal preparation. MATERIALS AND METHODS Forty Endo-Training Blocks (REF A 0177, Dentsply Maillefer) were used. They were divided into 4 groups. For groups 1, 2, 3, and 4, the glide path was established with ISO #13 Path File (Dentsply Maillefer), #...
متن کاملAn In Vitro Comparison of Root Canal Transportation by Reciproc File With and Without Glide Path
OBJECTIVE The aim of ideal canal preparation is to prevent iatrogenic aberrations such as transportation. The aim of this study was to evaluate the root canal transportation by Reciproc file with and without glide path. MATERIALS AND METHODS Thirty acrylic-resin blocks with a curvature of 60° and size#10 (2% taper) were assigned into two groups (n= 15). In group 1, the glide path was performe...
متن کاملEffect of glide path preparation on apical extrusion of debris in root canals instrumented with three single-file systems: An ex vivo comparative study
AIM The aim of this study was to test the effect of new protocol of glide path preparation by 20/0.04 rotary file on apical extrusion of debris when instrumenting fine curved mesial canals in mandibular molars with Self-adjusting File (SAF) and compare it to a glide path prepared by 20/0.02 hand K-file and rotary OneShape (OS) and reciprocating WaveOne (WO) file instrumentation. MATERIALS AND...
متن کاملComparison of apical extrusion of intracanal bacteria by various glide-path establishing systems: an in vitro study
Objectives This study compared the amount of apically extruded bacteria during the glide-path preparation by using multi-file and single-file glide-path establishing nickel-titanium (NiTi) rotary systems. Materials and Methods Sixty mandibular first molar teeth were used to prepare the test apparatus. They were decoronated, blocked into glass vials, sterilized in ethylene oxide gas, infected ...
متن کامل