Thermal calibration of photodiode sensitivity for atomic force microscopy

نویسندگان

  • Phil Attard
  • Torbjörn Pettersson
  • Mark W. Rutland
چکیده

The photodiode sensitivity in the atomic force microscope is calibrated by relating the voltage noise to the thermal fluctuations of the cantilever angle. The method accounts for the ratio of the thermal fluctuations measured in the fundamental vibration mode to the total, and also for the tilt and extended tip of the cantilever. The method is noncontact and is suitable for soft or deformable surfaces where the constant compliance method cannot be used. For hard surfaces, the method can also be used to calibrate the cantilever spring constant. © 2006 American Institute of Physics. DOI: 10.1063/1.2387891

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Step-edge calibration of torsional sensitivity for LFM

A novel calibration technique has been developed for lateral force microscopy (LFM). Typically, special preparation of the atomic force microscope (AFM) cantilever or a substrate is required for LFM calibration. The new calibration technique reported in this paper greatly reduces the required preparation processes by simply scanning over a rigid step and measuring the response of the AFM photod...

متن کامل

Thermomechanical noise of a free v-shaped cantilever for atomic-force microscopy.

We have calculated the thermal noise of a v-shaped AFM cantilever (Microlever, Type E, Thermomicroscopes) by means of a finite element analysis. The modal shapes of the first 10 eigenmodes are displayed as well as the numerical constants, which are needed for the calibration using the thermal noise method. In the first eigenmode, values for the thermomechanical noise of the z-displacement at 22...

متن کامل

A novel technique for the in situ calibration and measurement of friction with the atomic force microscope

Presented here is a novel technique for the in situ calibration and measurement of friction with the atomic force microscope that can be applied simultaneously with the normal force measurement. The method exploits the fact that the cantilever sits at an angle of about 10° to the horizontal, which causes the tip or probe to slide horizontally over the substrate as a normal force run is performe...

متن کامل

Calibration of lateral force measurements in atomic force microscopy with a piezoresistive force sensor.

We present here a method to calibrate the lateral force in the atomic force microscope. This method makes use of an accurately calibrated force sensor composed of a tipless piezoresistive cantilever and corresponding signal amplifying and processing electronics. Two ways of force loading with different loading points were compared by scanning the top and side edges of the piezoresistive cantile...

متن کامل

Calibration of colloid probe cantilevers using the dynamic viscous response of a confined liquid

Articles you may be interested in Adhesive-free colloidal probes for nanoscale force measurements: Production and characterization Rev. Improved in situ spring constant calibration for colloidal probe atomic force microscopy Rev. Accurate noncontact calibration of colloidal probe sensitivities in atomic force microscopy Rev. A calibration method for lateral forces for use with colloidal probe f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006