Mr Renography: Coherence Investigation between Thin Slab and Whole Kidney Scans

نویسندگان

  • B. Chen
  • Y. Dang
  • X. Yang
  • J. Fang
  • X. Wang
  • J. Zhang
چکیده

Purpose: Dynamic Contrast-Enhanced MR Renography (MRR) has the potential to provide useful renal functional information to evaluate renal diseases, especially the diffuse renal disease. The MRR is obtained along with dynamic renal perfusion after administration of an intravenous bolus of gadopentetate dimeglumine, and thus has an advantage of noninvasive examination [1]. However, generation of MR renographic curves currently takes at least ten minutes within the clinical setting, and higher temporal resolution is expected to improve the analysis of renal perfusion [2]. The purpose of this study was to determine whether the MRR of the center coronal thin slab scan can effectively represent the renal functional information in patients with diffuse renal disease.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Computer aided detection of acute renal allograft dysfunction using dynamic contrast enhanced MRI

osting by E Abstract Aim of the work: To evaluate the feasibility of dynamic contrast enhanced (DCE) MR Renography (MRR) in evaluation of renal allograft dysfunction using the computer based technique for motion correction and creation of renographic curves. Materials and methods: Between April 2007 and March 2008, 55 consecutive patients underwent kidney transplantation at our center from live...

متن کامل

Single Kidney GFR Measured using 3D MR Renography and a Multicompartmental Model

Synopsis A multicompartmental tracer kinetic model permits analysis of 3D MR renography data in terms of physiologic parameters such as glomerular filtration rate. Validation studies were performed in nine subjects, in whom single kidney GFR measurements were measured using radionuclide clearance methods. Agreement between model-fit values of SKGFR and reference values was high (r=0.77). Other ...

متن کامل

Dynamic three-dimensional MR renography for the measurement of single kidney function: initial experience.

A three-dimensional magnetic resonance (MR) renographic method to measure single kidney glomerular filtration rate (GFR) and split renal function was developed that is based on renal signal intensity measurements during 2-3 minutes after intravenous injection of a low dose (2 mL or 0.01 mmol/kg) of gadopentetate dimeglumine. In nine subjects, single kidney MR GFR indices correlated well with te...

متن کامل

Dynamic contrast-enhanced MR renography for renal function evaluation in ureteropelvic junction obstruction: feasibility study.

OBJECTIVE The purpose of this study was to evaluate split renal function, estimate single-kidney renal function, and identify cause of obstruction in patients with ureteropelvic junction (UPJ) obstruction by using contrast-enhanced dynamic MR renography (MRR). MATERIALS AND METHODS Seventeen patients with UPJ obstruction underwent MRR and diuresis nuclear renography. Nuclear renography assess...

متن کامل

Renal function measurements from MR renography and a simplified multicompartmental model.

The purpose of this study was to determine the accuracy and sources of error in estimating single-kidney glomerular filtration rate (GFR) derived from low-dose gadolinium-enhanced T1-weighted MR renography. To analyze imaging data, MR signal intensity curves were converted to concentration vs. time curves, and a three-compartment, six-parameter model of the vascular-nephron system was used to a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010