Root canal retreatment using reciprocating and continuous rotary nickel-titanium instruments

نویسندگان

  • Patricia Fonseca de Souza
  • Leonardo Cantanhede Oliveira Goncalves
  • Andre Augusto Franco Marques
  • Emilio Carlos Sponchiado Junior
  • Lucas da Fonseca Roberti Garcia
  • Fredson Marcio Acris de Carvalho
چکیده

OBJECTIVE The complete filling material removal during endodontic retreatment is a clinical procedure difficult to achieve. The aim of this study was to evaluate the efficacy of reciprocating and continuous rotary nickel-titanium instruments used in root canal retreatment. MATERIALS AND METHODS Forty freshly extracted human premolars were cleaned and shaped by the crown-down technique, followed by filling by the lateral compaction technique. The teeth were randomly separated into two groups (n = 20), according to the system used for filling material removal: G1 - Reciproc and G2 - ProTaper Universal Retreatment System. The teeth were photographed under operating microscope at ×8 magnification; and the total area of the root canal and remaining filling material were quantified. RESULTS No statistically significant difference (P > 0.05) in residual filling material was observed between groups; however, the time required for filling removal was significantly shorter for Reciproc system (P < 0.05). CONCLUSIONS It was observed remaining filling material in all teeth, irrespective of the system used; however, root canal retreatment was faster when reciprocating motion was used.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the amount of apically extruded debris during retreatment using different nickel-titanium systems and hand instruments in teeth with wide apices

Objective: The purpose of this study was to compare the apically extruded debris during endodontic retreatment of teeth with open apices using hand instruments and rotary instruments with continuous rotation and reciprocation. Methodology: Forty-five single-rooted maxillary incisors and canines were used. The root tips were dissected and #1 Gates Glidden burs were allowed to protrude 1 mm beyon...

متن کامل

Efficacy of 2 reciprocating systems compared with a rotary retreatment system for gutta-percha removal.

INTRODUCTION The maximum removal of root canal filling material is essential for successful endodontic retreatment. The purpose of this study was to assess the efficacy of 2 reciprocating systems (Reciproc [VDW, Munich, Germany] and WaveOne [Dentsply Maillefer, Ballaigues, Switzerland]) compared with a nickel-titanium (NiTi) rotary system (ProTaper Universal Retreatment [Dentsply Maillefer]) in...

متن کامل

Efficacy of CM-Wire, M-Wire, and Nickel-Titanium Instruments for Removing Filling Material from Curved Root Canals: A Micro-Computed Tomography Study.

INTRODUCTION The aim of this ex vivo study was to evaluate the removal of filling material after using CM-wire, M-wire, and nickel-titanium instruments in both reciprocating and rotary motions in curved canals. METHODS Thirty maxillary lateral incisors were divided into 9 groups according to retreatment procedures: Reciproc R25 followed by Mtwo 40/.04 and ProDesign Logic 50/.01 files; ProDesi...

متن کامل

In vitro evaluation of efficacy of different rotary instrument systems for gutta percha removal during root canal retreatment

BACKGROUND Complete removal of old filling material during root canal retreatment is fundamental for predictable cleaning and shaping of canal anatomy. Most of the retreatment methods tested in earlier studies have shown inability to achieve complete removal of root canal filling. Therefore the aim of this investigation was to assess the efficacy of three different rotary nickel titanium retrea...

متن کامل

TF TM Adaptive : a novel approach to nickel - titanium instrumentation

instruments have been traditionally used with a continuous rotary motion, but more recently, a new approach to the use of nickel-titanium instruments in a reciprocating movement has been introduced by Yared (2004). The clockwise (CW) and counter-clockwise (CCW) rotations used by Yared were four-tenths and two-tenths of a circle respectively, and the rotational speed utilized was 400 rpm. The co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2015