Development of an Accident Reproduction Simulator System Using a Hemodialysis Extracorporeal Circulation System.

نویسندگان

  • Yoshiaki Nishite
  • Shingo Takesawa
چکیده

BACKGROUND Accidents that occur during dialysis treatment are notified to the medical staff via alarms raised by the dialysis apparatus. Similar to such real accidents, apparatus activation or accidents can be reproduced by simulating a treatment situation. An alarm that corresponds to such accidents can be utilized in the simulation model. OBJECTIVES The aim of this study was to create an extracorporeal circulation system (hereinafter, the circulation system) for dialysis machines so that it sets off five types of alarms for: 1) decreased arterial pressure, 2) increased arterial pressure, 3) decreased venous pressure, 4) increased venous pressure, and 5) blood leakage, according to the five types of accidents chosen based on their frequency of occurrence and the degree of severity. MATERIALS AND METHODS In order to verify the alarm from the dialysis apparatus connected to the circulation system and the accident corresponding to it, an evaluation of the alarm for its reproducibility of an accident was performed under normal treatment circumstances. The method involved testing whether the dialysis apparatus raised the desired alarm from the moment of control of the circulation system, and measuring the time it took until the desired alarm was activated. This was tested on five main models from four dialyzer manufacturers that are currently used in Japan. RESULTS The results of the tests demonstrated successful activation of the alarms by the dialysis apparatus, which were appropriate for each of the five types of accidents. The time between the control of the circulatory system to the alarm signal was as follows, 1) venous pressure lower limit alarm: 7 seconds; 2) venous pressure lower limit: 8 seconds; 3) venous pressure upper limit: 7 seconds; 4) venous pressure lower limit alarm: 2 seconds; and 5) blood leakage alarm: 19 seconds. All alarms were set off in under 20 seconds. CONCLUSIONS Thus, we can conclude that a simulator system using an extracorporeal circulation system can be set to different models of dialyzers, and that the reproduced treatment scenarios can be used for simulation training.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In medical education, simulator-based education is gain- ing widespread acceptance as a teaching tool within the field

In medical education, simulator-based education is gaining widespread acceptance as a teaching tool within the field of anesthesiology (1,2). The particular advantage of medical simulations is the fact that no harm can come to patients (3). Simulation training is particularly useful for learning to manage rare or infrequent events (4). To learn to manage various events, trainees have to underst...

متن کامل

Virtual patient simulator for the perfusion resource management drill.

Perfusionists require a detailed understanding of a patient's physiological status while comprehending the mechanics and engineering of the cardiopulmonary bypass system, so it is beneficial for them to obtain relevant practical skills using extracorporeal circulation technology and educational physiological simulators. We designed a perfusion simulator system (ECCSIM: Extracorporeal Circulatio...

متن کامل

Vascular Access for Hemodialysis

Patients with acute kidney failure (AKF) and chronic kidney failure (CKF) require an appropriate vascular access for hemodialysis [1]. Vascular access is needed to allow blood flow through an extracorporeal circulation system with a blood pump connected to a hemodialysis monitor driving the blood through a dialysis filter (dialysator). Satisfactory levels of blood flow range between 300 and 400...

متن کامل

Tracheal Chondrosarcoma Excised With Extracorporeal Circulation

Introduction: Tracheal chondrosarcoma (TCS) is a rare malignancy, with only 19 cases described in the literature to date. Case presentation: Herein, we presented the third-largest TCS with such an airway compromise that neither orotracheal intubation nor jet ventilation or even tracheostomy was possible. So, extracorporeal circulation was needed to excise the tumor in a one-stage procedure. Th...

متن کامل

Comparing the Effects of Three Heparinization Methods of Hemodialysis Set on the Amount of Clot Formation during Hemodialysis

Background: Nowadays, the most important aspect of hemodialysis is the technical method of anticoagulation of extracorporeal circuit. This quasi-experimental study was performed to compare three methods of heparinization in the extracorporeal circulation. Methods: Twenty-seven hemodialysis patients referring to Rafsanjan Hemodialysis Center with the weight range of 50-90 kg and normal Clotting ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nephro-urology monthly

دوره 8 1  شماره 

صفحات  -

تاریخ انتشار 2016