Digital photogrammetry for quantitative wear analysis of retrieved TKA components.

نویسندگان

  • J C Grochowsky
  • L W Alaways
  • R Siskey
  • E Most
  • S M Kurtz
چکیده

The use of new materials in knee arthroplasty demands a way in which to accurately quantify wear in retrieved components. Methods such as damage scoring, coordinate measurement, and in vivo wear analysis have been used in the past. The limitations in these methods illustrate a need for a different methodology that can accurately quantify wear, which is relatively easy to perform and uses a minimal amount of expensive equipment. Off-the-shelf digital photogrammetry represents a potentially quick and easy alternative to what is readily available. Eighty tibial inserts were visually examined for front and backside wear and digitally photographed in the presence of two calibrated reference fields. All images were segmented (via manual and automated algorithms) using Adobe Photoshop and National Institute of Health ImageJ. Finally, wear was determined using ImageJ and Rhinoceros software. The absolute accuracy of the method and repeatability/reproducibility by different observers were measured in order to determine the uncertainty of wear measurements. To determine if variation in wear measurements was due to implant design, 35 implants of the three most prevalent designs were subjected to retrieval analysis. The overall accuracy of area measurements was 97.8%. The error in automated segmentation was found to be significantly lower than that of manual segmentation. The photogrammetry method was found to be reasonably accurate and repeatable in measuring 2-D areas and applicable to determining wear. There was no significant variation in uncertainty detected among different implant designs. Photogrammetry has a broad range of applicability since it is size- and design-independent. A minimal amount of off-the-shelf equipment is needed for the procedure and no proprietary knowledge of the implant is needed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rock mass structural characterization via short-range digital photogrammetry

Because of the important role of rock mass structural properties on its mechanical behavior, determining the qualitative and quantitative properties of has been a subject of intense research. In this regard, numerous techniques such as scanline surveying, cell mapping, and geologic structure mapping have been proposed. However, applying such field surveying techniques for rock mass properties i...

متن کامل

A field investigation of application of digital terrestrial photogrammetry to characterize geometric properties of discontinuities in open-pit slopes

In order to analyze the slope stability in open-pit mines, the structural parameters of rock mass such as persistence and spatial orientation of discontinuities are characterized through field surveys, which involve spending high costs and times as well as posing high risks of rock toppling and rock fall. In the present work, a new application of terrestrial digital photogrammetry is introduced...

متن کامل

Advantages of Mobile-bearing Total Knee Arthroplasty

Early historical failure of total knee arthroplasty (TKA) was frequently secondary to aseptic loosening, often associated with malalignment, instability, or use of excessively constrained prosthetic components. With the addition of better surgical instrumentation and operative techniques (ligamentous balancing, improved alignment, etc.) and the use of lowerconformity prosthetic devices, looseni...

متن کامل

CR TKA UHMWPE Wear Tested after Artificial Aging of the Vitamin E Treated Gliding Component by Simulating Daily Patient Activities

The wear behaviour of total knee arthroplasty (TKA) is dominated by two wear mechanisms: the abrasive wear and the delamination of the gliding components, where the second is strongly linked to aging processes and stress concentration in the material. The addition of vitamin E to the bulk material is a potential way to reduce the aging processes. This study evaluates the wear behaviour and dela...

متن کامل

Biotribology in Knee Arthroplasty

During the last decade, new bearing materials, new methods in in vitro wear simulation, specific cell culture, and animal models to evaluate the response to particulate debris, and dedicated retrieval analysis programs to learn more about material degradation in vivo have been developed in the field of biotribology. Improvements in knee arthroplasty design, materials, sterilisation techniques, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomedical materials research. Part B, Applied biomaterials

دوره 79 2  شماره 

صفحات  -