Visualisation of active subretinal implants with external connections by high-resolution CT.
نویسندگان
چکیده
Two patients carrying an active subretinal implant with extra-ocular parts were examined by high-resolution CT. Cranial scans were acquired in the primary position and in eight additional directions of gaze with eyes open and closed to demonstrate the mobility of the eyeball and the implant within the orbital cavity. Three-dimensional images were constructed to visualise the path of the implant from the retro-auricular space around the lateral orbital rim through the orbit and within the subretinal space up to the device's final para-foveal position. Images were obtainable in high quality, resulting in three-dimensional models illustrating all parts of the implant including the micro-photodiode array at the tip in the subretinal space. The implant followed eye movements in all directions of gaze; eye movements were only minimally restricted as described in previous publications. Since all, except intra-ocular, parts of the implant evade direct examination, CT can be useful to assess the technical integrity and the biocompatibility and biostability of retinal implants.
منابع مشابه
Clinical Parameters and Crestal Bone Loss in Internal Versus External Hex Implants at One Year after Loading
Introduction: The survival of an implant system is affected by the choice of antirotational design, which can include an external or internal hex. Implant success also is affected by the maintenance of the crestal bone around implants. The aim of present study was to evaluate the crestal bone loss and clinical parameters related to bone loss in patients loaded with an external or internal hex 3...
متن کاملExtraocular surgery for implantation of an active subretinal visual prosthesis with external connections: feasibility and outcome in seven patients.
BACKGROUND Due to low energy levels in microphotodiode-based subretinal visual prostheses, an external power supply is mandatory. We report on the surgical feasibility and the functional outcome of the extraocular part of an approach to connect a subretinal prosthesis to an extracorporeal connector in the retro-auricular space via a trans-scleral, transchoroidal cable. METHODS Seven volunteer...
متن کاملDesign and Fabrication Process of MTF Phantom CT Scan
Introduction: One of the main steps in the optimization process in diagnostic imaging is the quality control of radiology devices. The usual method of CT scan calibration is used of a phantom. The phantom created a certain weakening for the radiation through which it passes. One of the most suitable methods for quantitative analysis of the resolution and contrast in CT scan im...
متن کاملCLASSIFICATION OF CONGENITAL MIDDLE AND EXTERNAL EAR MALFORMATIONS: CT STUDY
The authors used high-resolution computed tomography (HRCT) for studying 52 congenitally malformed ears in 45 children between five and 10 years of age. In six children the malformations were bilateral. The malformations clinically manifested as microtia, atresia of the external auditory canal and conductive deafness. Analyzing anatomical details and pathological changes on HRCT axial sec...
متن کاملEffect of GapSeal® as a Sealing Material on Microgap and Microleakage at External Hexagon Implant Connections Following Cyclic Loading: An In Vitro Study
Background and Aim: The mismatch of the implant-abutment connection can produce instant stress and microleakage which result in mechanical and biological complications. This study aimed to investigate the influence of GapSeal® as a sealing material on the extent of microgap and microleakage at the external hexagon implant platform following cyclic loading. Materials and Methods: Sixteen implan...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 94 7 شماره
صفحات -
تاریخ انتشار 2010