Measurement of Immersion Suit Insulation: a Comparison between Human Subjects and a Thermal Manikin

نویسندگان

  • M. B. Ducharme
  • C. J. Brooks
  • P. Potter
چکیده

Thermal manikin. Parallel to the human tests, the immersion suit was also tested using a Thermal Instrumented Manikin (TIM, CORD Group Limited, Dartmouth, Nova Scotia) immersed in the same water conditions and at the same time without interfering with the subject or changing the wave pattern. The probe locations (except for the location of the lIFTs that were fixed on the pile garment of the manikin instead of the skin as it was for the humans to avoid applying a large correction factor to the heat flow values; see 2) and the clothing were the same as for the human subjects (see 1 for details). The aluminum skin of the manikin was maintained constant and uniform at 25°C during the tests.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of Standard Wave Conditions on Dry Suit Insulation When Measured on Humans

Testing of immersion suits is commonly conducted in calm or circulatory water. Several investigators have argued that this is an unrealistic test for a suit that is designed to protect a human from hypothermia in open ocean conditions. In support of this argument, Steinman et al. (1) and Romet et al.(2) reported a significant reduction of suit insulation in turbulent water when compared to stil...

متن کامل

Effect of clothing ventilation on thermal insulation and vapor resistance

In this study, ventilation of clothing microenvironment, thermal insulation and vapor resistance of two jackets made of different materials were measured locally at front, back, side and arm by using an articulated thermal manikin in a controlled climate chamber (29±1°C, 40±10%RH). The various conditions of microenvironment ventilation were created by making the manikin stand and walk, combined...

متن کامل

Thermal manikin measurements--exact or not?

According to the European prestandard ENV 342:1998, the thermal insulation of cold-protective clothing is measured with a thermal manikin. Systematic studies on the reproducibility of the values, measured with different types of clothing on the commonly used standing and walking manikins, have not been reported in the literature. Over 300 measurements were done in 8 different European laborator...

متن کامل

Evaluating cold, wind, and moisture protection of different coverings for prehospital maritime transportation-a thermal manikin and human study.

INTRODUCTION Prehospital maritime transportation in northern areas sets high demands on hypothermia prevention. To prevent body cooling and hypothermia of seriously-ill or injured casualties during transportation, casualty coverings must provide adequate thermal insulation and protection against cold, wind, moisture, and water splashes. OBJECTIVE The aim of this study was to determine the the...

متن کامل

Thermal-insulation performance of low density polyethylene (LDPE) foams: Comparison between two radiation thermal conductivity models

The loss of energy especially in industrial and residential buildings is one of the main reasons of increased energy consumption. Improving the thermal insulation properties of materials is a fundamental method for reducing the energy losses. Polymeric foams are introduced as materials with excellent thermal insulation properties for this purpose. In the present study, a deep theoretical invest...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005