The off-pump technique in redo coronary artery bypass grafting reduces mortality and major morbidities: propensity score analysis of data from the Japan Cardiovascular Surgery Database†.
نویسندگان
چکیده
OBJECTIVES The benefits of off-pump coronary artery grafting (OPCAB) have been demonstrated. Especially in patients with a high number of comorbidities, redo coronary artery bypass grafting (CABG) remains a difficult entity of CABG, because patients are likely to have multiple risk factors and often have diseased patent grafts with adhesions. The aim of the present study was to evaluate the effects of the OPCAB technique in redo CABG on mortality and morbidity using data from the Japan Cardiovascular Surgery Database (JCVSD). METHODS We analysed 34 980 patients who underwent isolated CABG between 2008 and 2011, as reported in the JCVSD. Of these, 1.8% of patients (n = 617/34980) had undergone redo CABG, including those who underwent OPCAB (n = 364; 69%) and on-pump CABG (n = 253; 41%). We used propensity score (PS) matching with 13 preoperative risk factors to adjust for differences in baseline characteristics between the redo OPCAB and on-pump redo CABG groups. By one-to-one PS matching, we selected 200 pairs from each group. RESULTS There were no significant differences in patient background between the redo OPCAB and on-pump redo CABG groups after PS matching. There was no significant difference in the mean number of distal anastomoses after matching (2.41 ± 1.00 vs 2.21 ± 1.04, P = 0.074); nevertheless, the mean operation time was significantly shorter in the redo OPCAB than the on-pump redo CABG group (353.7 vs 441.3 min, P < 0.00010). Patients in the redo OPCAB group had a lower 30-day mortality rate (3.5 vs 7.0%, P = 0.18), a significantly lower rate of composite mortality or major morbidities (11.0 vs 21.5%, P = 0.0060), a significantly lower rate of prolonged ventilation (>24 h) (7.0 vs 15.0%, P = 0.016), a significantly shorter duration of intensive care unit (ICU) stay (ICU stay ≥ 8 days) (7.0 vs 14.5%, P = 0.023) and a significantly decreased need for blood transfusions (71.5 vs 94.0%, P < 0.00010) than patients in the on-pump redo CABG group. CONCLUSION The off-pump technique reduced early operative mortality and the incidences of major complications in redo CABG.
منابع مشابه
A Propensity Score Analysis of Renal Dysfunction in Patients after On-Pump and Off-Pump Coronary Artery Bypass Surgery
INTRODUCTION- Cardiovascular disease has emerged as a major health burden worldwide with coronary artery disease [CAD] causing highest mortality and morbidity. Coronary revascularization is the preferred treatment for patients with multivessel CAD. Based on the application of cardiopulmonary bypass [CPB], Coronary revascularization can be on-pump [OPCAB] or off-pump [CABG].The CPB is known to h...
متن کاملAvoidance of Dialysis in an End-Stage Renal Disease Patient Status-post Off-pump Coronary Artery Bypass Grafting
Certain benefits are clearly associated with the use of off-pump coronary artery bypass grafting (CABG) as compared with the on-pump CABG. The superiority is more evident in patients with multiple co morbidities including renal failure.We reviewed the medical records of a 67-year-old male with a past medical history that was significant for multiple cardiovascular diseases and new-onset end-sta...
متن کاملOff-Pump Versus On-Pump Coronary Artery Bypass Graft Surgery, prospective cohort study
Introduction: Coronary artery bypass grafting is a surgical operation that bypasses atherosclerotic coronary vessels and restores blood flow to the ischemic zone of hearts. And two different conventional methods are ON-pump CABG, and Off-pump CABG. Altogether, the efficacy and safety of these two types of surgical procedures are still under debate. In this study, we aim to com...
متن کاملUse of Carbon dioxide versus air blower in on-pump beating-heart coronary artery bypass surgery
Introduction: The use of carbon dioxide blower has been recognized as the standard of care in patients undergoing beating coronary artery bypass grafting (CABG) due to higher solubility and lower risk of embolization. On the other hand, the compressed air blower has gone out of use since air can be easily trapped and is less soluble which can cause coronary embolism. The prese...
متن کاملComparison of Treatment Outcomes in Off-pump Coronary Artery Bypass Graft and Medical Therapy in Patients with Triple-vessel Coronary Artery Disease and Severe Ventricular Dysfunction
Introduction: Heart failure is a major hazard for public health. Despite recent advance in medical therapy, there is not enough information on the outcome of off-pump coronary artery bypass (OPCAB) and medical therapy on the patients with severe ventricular dysfunction and triple-vessel (CAD). This study aimed to compare treatment outcomes and mortality rate in patients undergoing off-pump coro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
دوره 47 2 شماره
صفحات -
تاریخ انتشار 2015