Microcontroller Based Temperature Monitoring and Closed Loop Control to Study the Reaction of Controlled Variable with Respect to Load Changes
نویسنده
چکیده
The objective of the present paper is designing 8051 microcontroller based temperature control system to study the reaction of controlled variable with respect to load changes. The process temperature under control is measured using RTD. Then using a microcontroller and suitable software, this instantaneous value of temperature is compared with the desired temperature. The resulting error has been used by the microcontroller to control the firing angle of a TRIAC for controlling the power applied to the heater. The trigger pulse for the TRIAC is delayed by the microcontroller to provide the required voltage to be fed to the heater to get the desired temperature. Thus a continuous closed loop temperature monitoring and control has been achieved. The proportional control scheme has been described in the present paper. The behavior of the process temperature has been studied with respect to load changes. Experimental results have been presented to study the reaction of controlled variable or process temperature with respect to load changes. Copyright © 2013 IFSA.
منابع مشابه
Dynamic Load Carrying Capacity of Mobile-Base Flexible-Link Manipulators: Feedback Linearization Control Approach
This paper focuses on the effects of closed- control on the calculation of the dynamic load carrying capacity (DLCC) for mobile-base flexible-link manipulators. In previously proposed methods in the literature of DLCC calculation in flexible robots, an open-loop control scheme is assumed, whereas in reality, robot control is achieved via closed loop approaches which could render the calculated ...
متن کاملExperimental investigations on a pre-chamber spark plug with variable heat range by integrating a controlled hot surface
In gasoline engines, pre-chamber spark ignition systems are used to achieve high efficiency and low NOx emissions when operating under lean conditions. While a cold pre-chamber spark plug can lead to misfiring and flame quenching under cold start or part load operation, a hot pre-chamber can result in uncontrolled pre-ignition phenomena under full load operation. This paper presents an approach...
متن کاملDevelopment of hardware system using temperature and vibration maintenance models integration concepts for conventional machines monitoring: a case study
This article describes the integration of temperature and vibration models for maintenance monitoring of conventional machinery parts in which their optimal and best functionalities are affected by abnormal changes in temperature and vibration values thereby resulting in machine failures, machines breakdown, poor quality of products, inability to meeting customers’ demand, poor inventory contro...
متن کاملSimulation and Experimental Verification of Closed Loop Operation of Buck / Boost DC-DC Converter with Soft Switching
A major problem in an isolated DC/DC converters operating at high switching frequencies is the attendant switching losses in the semiconductor devices. This can be reduced by introducing either zero-voltage switching (ZVS) or zero-current switching (ZCS) of the semiconductor switches. This paper deals with the simulation, design, fabrication and experimental evaluation of a novel soft-switching...
متن کاملIoT Based Load Management of a Micro-Grid Using Arduino and HMAS
This paper aims to establish an Arduino and IoT-based Hierarchical Multi-Agent System (HMAS) for management of loads’ side with incentive approach in a micro-grid. In this study, the performance of the proposed algorithm in a micro-grid has been verified. The micro-grid contains a battery energy storage system (BESS) and different types of loads known as residential consumer (RC), commercial co...
متن کامل