چکیده

Most confocal microscopes do not produce images in real time with nonlaser light sources. The tandem scanning confocal microscope does produce such images but, because the pinhole apertures of the Nipkov disk must be placed far apart to reduce cross talk between neighboring pinholes, only 1% or less of the light available for imaging is used. We show that, by using aperture correlation techniques and relaxing the requirement to obtain a pure confocal image directly, one can obtain real-time confocal images with a dramatically increased (25% or even 50%) light budget.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Confocal microscopy with an increased detection aperture: type-B 4Pi confocal microscopy.

We show the point-spread function of a confocal microscope with an increased detection aperture. The increase in aperture is accomplished by coherent collection of the light from the specimen with two opposing objective lenses, i.e., type-B 4Pi confocal microscopy. We demonstrate experimentally its feasibility for detecting scattered or fluorescently emitted light. The 4Pi confocal point-spread...

متن کامل

REVIEW Confocal scanning optical microscopy and its applications for biological specimens

Confocal scanning optical microscopy (CSOM) is a new optical microscopic technique, which offers significant advantages over conventional microscopy. In laser scanning optical microscopy (SOM), the specimen is scanned by a diffractionlimited spot of laser light, and light transmitted or reflected by the in-focus illuminated volume element (voxel) of the specimen, or the fluorescence emission ex...

متن کامل

Variations of the Normal Human Limbal Stem Cells Detected by In Vivo Confocal Microscopy

Background  To report normal variations of the limbal structures using in vivo laser scanning confocal microscopy. Methods: This was a retrospective study of fourteen eyes from 11 healthy individuals. Confocal imaging of cornea and limbus was performed using Heidelberg Retina Tomograph III Rostock Corneal Module. Results: The typical structure of the palisades of Vogt (POV) was detected ...

متن کامل

Confocal theta fluorescence microscopy using two-photon absorption and annular apertures

Confocal theta fluorescence microscopy using two-photon absorption and annular apertures. In a confocal theta fluorescence microscope, a second objective lens placed orthogonally to the illumination objective lens is used for detection. The addition of annular apertures to such an arrangement leads to a reduction of the volume at half maximum of the point spread function. We show that when the ...

متن کامل

Choosing objective lenses: the importance of numerical aperture and magnification in digital optical microscopy.

Microscopic images are characterized by a number of microscope-specific parameters--numerical aperture (NA), magnification (M), and resolution (R)--and by parameters that also depend on the specimen--for example, contrast, signal-to-noise ratio, dynamic range, and integration time. In this article, issues associated with the microscope-specific parameters NA, M, and R are discussed with respect...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics letters

دوره 21 23  شماره 

صفحات  -

تاریخ انتشار 1996