Counting efficiency of a double-well single-plastic scintillation counter to commercially available radionuclides (Tl-201, Tc-99m, I-123, Ga-67, In-111 and I-131).

نویسندگان

  • Kazuo Itoh
  • Kimikazu Sasaki
چکیده

UNLABELLED A new type of well-scintillation counter with a double-well and single-plastic scintillator (DW-counter) was developed to simplify time consuming and cumbersome dilution procedures inherent to in-vivo sample measurement. It has the potential to measure many radionuclides which emit a gamma ray or positron. We tested the counting efficiency (CE) of the DW-counter (DCM-200, Aloka Co., Tokyo, Japan) with respect to 6 radionuclides. MATERIALS AND METHODS The outline of DW-counter is altered to a single unit as compared to the prototype, while its basic mechanical constitution was not changed. Six commercially available radionuclides (Tl-201, Tc-99m, I-123, Ga-67, In-111, I-131) were used in this study. For each radionuclide, we prepared two standard solutions containing high (>100 MBq/ml) and relatively low radioactivity (10-20 MBq/ml). The radioactivity (Bq) of the radionuclide in each sample at time = 0 was measured with a dose calibrator. Afterwards, it was determined from a decay-time with correction by the physical half-life of each radionuclide. Count rate (cps) of each standard sample was measured in each well ten times per sample. The counting efficiency (CE) of the counter for each radionuclide was determined by measured count rate (cps)/standard radioactivity (Bq) x 100 (%). The conversion constant (CC) which predicts standard radioactivity (Bq) from measured count rate (cps) was obtained as a reciprocal value of the CE. RESULTS The CE (mean +/- SD) in well-A to Tl-201, Tc-99m, I-123, Ga-67, In-111 and I-131 was 5.90 +/- 0.285%, 8.56 +/- 0.0981%, 8.33 +/- 0.344%, 7.77 +/- 0.15%, 16.4 +/- 0.495% and 10.2 +/- 0.139%, respectively. They were significantly different. The coefficient of variation of the measured count rates was less than 1% in radioactive range higher than 10(3) Bq in well-A and 106 Bq in well-B. The difference in the CE between well-A and -B ranged from 7.614 x 10(2) (I-131) to 9.395 x 10(2) (Tl). The CC ranged from 6.14 (In) to 17.15 (Tl) in well-A and from 5.05057 x 10(3) (In) to 15.83773 x 10(3) (Tl) in well-B. The CE was not significantly affected by a sample volume from 1 to 4 ml in well-A, but showed a slight difference in well-B, which seemed due to a collimation. CONCLUSION The measurement error of the DW-counter was less than 1% and the measured count rate (cps) was exactly converted to the standard radioactivity (Bq) by determined CC. The counter is considered useful in the easy evaluation of in-vivo tracer kinetics by avoiding time consuming and cumbersome dilution techniques.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of different physical parameters that affect the clinical image quality for gamma camera by using different radionuclides

Some scintillation camera manufactures adhere to standard code of performance specification established by National Electric Manufactures Association (NEMA). Items such as differential and integral uniformity, spatial resolution energy resolution, etc. are all calculated with reproducible methodology that allows the user reliable technique for creation of these standards to avoid any lack of cl...

متن کامل

Nuclear Imaging of Amyloidosis

Summary Amyloidosis is a clinical condition caused by deposition of various protein fibrills in extracellular space. The presented symptoms depend on the type of deposits and the organ or organs involved. The correct diagnosis is often difficult, due to lack of nonivasive imaging techniques and insufficiency of morphological imaging procedures delievered by radiology. We presented a list of pot...

متن کامل

Diagnostic capabilities of I-131, TI-201, and Tc-99m-MIBI scintigraphy for metastatic differentiated thyroid carcinoma after total thyroidectomy.

We investigated the diagnostic capabilities of I-131, Tl-201, and Tc-99m-MIBI (hexakis-2-methoxyisobutyl- isonitrile) scintigraphy for thyroid cancer metastases after total thyroidectomy over the entire body and for every locus before and after thyroid bed ablation. After total thyroidectomy of thyroid cancer, 36 cases were subjected to I-131 treatment 64 times. They consisted of 17 men and 19 ...

متن کامل

Diagnostic Capabilities of I-131, Tl-201, and Tc-9 9 m-MIBI Scintigraphy for Metastatic Differentiated Thyroid Carcinoma after Total Thyroidectomy

We investigated the diagnostic capabilities of I-131, Tl-201, and Tc-99m-MIBI (hexakis-2-methoxyisobutyl-isonitrile) scintigraphy for thyroid cancer metastases after total thyroidectomy over the entire body and for every locus before and after thyroid bed ablation. After total thyroidectomy of thyroid cancer, 36 cases were subjected to I-131 treatment 64 times. They consisted of 17 men and 19 w...

متن کامل

Comparison of I-131, I-123 Absorbed Dose and Tc-99m in Thyroid Scanning Using MCNP Code in ORNL-MIRD Phantom

Introduction: Thyroid cancer is at the ninth from ten of common malignant cancer. A man has higher risk to get Thyroid cancer that a woman has. This organ is lain near human neck. The use of radioactive I-131, I-123 and Tc-99m for diagnosis of thyroid cancer has a risk where other organs around Thyroid will accept dose of radiation. One of the risks is large dose which is accep...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Annals of nuclear medicine

دوره 17 5  شماره 

صفحات  -

تاریخ انتشار 2003