Rotating-hinge total knee for revision total knee arthroplasty.
نویسندگان
چکیده
Rotating-hinge knee implants are used for revision total knee arthroplasty in patients with severe ligament instability and bone loss. This study evaluated the outcomes of a series of rotating-hinge knees. Thirty-one NexGen Rotating Hinge Knees (Zimmer, Warsaw, Indiana) were implanted in 29 patients (2 bilateral), with an average age of 72.8 years. Indications for surgery were aseptic loosening (n=23), septic loosenings (n=4), tibiofemoral instability (n=3), and wear (n=1). The Hospital for Special Surgery Knee Score and the Knee Society Roentgenographic Evaluation System were used. Statistical and cumulative survival rate analyses were performed. Average follow-up was 60.3 months (range, 32-100 months). The Hospital for Special Surgery Knee Score results indicated statistically significant improvement; the total score increased from 65.5 preoperatively to 88.4 postoperatively. Average range of motion increased from 90.9° preoperatively to 114.4° postoperatively. Radiographs showed no periprosthetic bone fractures or implant ruptures. Radiolucent lines were found in 20 of 26 patients and were progressive in 2 (both revised). Complications occurred in 10 patients. The rigidity of the hinge may be associated with a risk of aseptic loosening due to the increased stress transfer to the bone from the prosthesis through the locked hinge. Rotating-hinge knee implants provided acceptable mid-term outcomes for revision knee surgery with ligamentous instability. They are not at higher risk for early loosening unless short tibial stems are used. The high percentage of failures is more related to the complex surgery and to the status of the patients than to the hinged mechanism.
منابع مشابه
Endo-Modell rotating-hinge total knee for revision total knee arthroplasty.
The goal of this study was to analyze the clinical and radiographic results and the survival rate of a series of rotating-hinge implants used for revision total knee arthroplasties in mild and severe instability. Between December 1991 and June 2004, fifty-three revision total knee arthroplasties were performed using the Endo-Modell (Waldemar LINK GmbH and Co, Hamburg, Germany) rotating-hinge pr...
متن کاملRotating Hinge Total Knee Arthroplasty RT-PLUS Solution: A Clinical and Radiographic Follow-Up
Background: In total knee arthroplasty (TKA), there is still controversy surrounding the preferable prosthetic design and required amount of constraint. Indication for rotating hinge TKA includes primary and revision arthroplasty, with contradictory results. We present the first mediumto long-term results with the rotating hinge knee prosthesis RT-PLUS SOLUTION (Smith & Nephew Orthopaedics, Baa...
متن کاملGenu recurvatum as a complication after total knee arthroplasty.
A 73-year-old female patient underwent total knee arthroplasty for arthrosis. After surgery, recurvatum instability over 55 degrees occurred. Two years later, primary endoprosthesis was removed and a revision endoprosthesis implanted. However, complete deformity occurred again. Two years later, the thickest revision polyethylene tibial implant was implanted on the same endoprosthesis. In spite ...
متن کاملTotal Knee Arthroplasty in Severe Unstable Knee: Case-Report and Literature Review
Multiplanar or global laxity in arthritic knee is rare , most of this patients have neuromuscular disorder (post poliomyelitis , spinal dystrophy) or history of knee trauma. Ligament insufficiency and severe bone loss is significant in this patient. The estimated prevalence for the concurrence of charcot marie-tooth (CMT) with myasthenia gravis (MG) suggests an extremely rare event. We have p...
متن کاملPosterior Dislocation of the Hinge-Post Extension in a Rotating Hinge Total Knee Prosthesis
The rotating hinge knee prosthesis is a popular intervention in patients lacking stability with highly constrained total knee arthroplasty. Despite improvements in design, nonmechanical and mechanical complications continue to be a problem. Dislocation of the hinge has been widely described, mainly due to the component fracture. Few reports describe isolated dislocation of the rotating stem. We...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Orthopedics
دوره 35 3 شماره
صفحات -