Analog pixel array detectors.

نویسندگان

  • A Ercan
  • M W Tate
  • S M Gruner
چکیده

X-ray pixel array detectors (PADs) are generally thought of as either digital photon counters (DPADs) or X-ray analog-integrating pixel array detectors (APADs). Experiences with APADs, which are especially well suited for X-ray imaging experiments where transient or high instantaneous flux events must be recorded, are reported. The design, characterization and experimental applications of several APAD designs developed at Cornell University are discussed. The simplest design is a ;flash' architecture, wherein successive integrated X-ray images, as short as several hundred nanoseconds in duration, are stored in the detector chips for later off-chip digitization. Radiography experiments using a prototype flash APAD are summarized. Another design has been implemented that combines flash capability with the ability to continuously stream X-ray images at slower (e.g. milliseconds) rates. Progress is described towards radiation-hardened APADs that can be tiled to cover a large area. A mixed-mode PAD, design by combining many of the attractive features of both APADs and DPADs, is also described.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design Methodology: Edgeless 3D ASICs with complex in-pixel processing for Pixel Detectors

The design methodology for the development of 3D integrated edgeless pixel detectors with in-pixel processing using Electronic Design Automation (EDA) tools is presented. A large area 3 tier 3D detector with one sensor layer and two ASIC layers containing one analog and one digital tier, is built for x-ray photon time of arrival measurement and imaging. A full custom analog pixel is 65μm x 65μm...

متن کامل

X-ray Imaging Detector Using Silicon Field Emission Tip Array Energy Conversion

Existing x-ray detecting technologies can be classified as either photon-counting (digital) or integrating (analog). Multi-wire proportional counters (MVVPC) are digital detectors that have advantages such as high quantum sensitivity, high dynamic range, and high intrinsic energy resolution, and have a wide range of applications. However, most photon-counting detectors rely on gas conversion of...

متن کامل

An Infrared Camera for Leuschner Observatory and the Berkeley Undergraduate Astronomy Lab

We describe the design, fabrication, and operation of an infrared camera which is in use at the 30-inch telescope of the Leuschner Observatory. The camera is based on a Rockwell PICNIC 256×256 pixel HgCdTe array, which is sensitive from 0.9-2.5 μm. The primary purpose of this telescope is for undergraduate instruction. The cost of the camera has been minimized by using commercial parts whereeve...

متن کامل

Development of a small-scale prototype of the GOSSIPO-2 chip in 0.13 μm CMOS technology

The GOSSIP (Gas On Slimmed Silicon Pixel) detector is a proposed alternative for silicon based pixel detectors. The Gossip Prototype (GOSSIPO) chip is being developed to serve as a prototype read-out chip for such a gas-filled detector. Thanks to the very low capacitance at the preamplifier input, the front-end of the chip demonstrates low-noise performance in combination with a fast peaking ti...

متن کامل

Measurements of spatial resolution of ATLAS Pixel detectors

Standard as well as irradiated silicon pixel detectors developed for the ATLAS experiment were tested in a beam. Digital and analog resolutions were determined comparing the positions measured by a microstrip telescope and by the pixel detector. Digital resolutions of 10 μm and analog resolutions of 6 μm (before irradiation) and 10 μm (after irradiation) are obtained without subtracting the err...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of synchrotron radiation

دوره 13 Pt 2  شماره 

صفحات  -

تاریخ انتشار 2006