Analytical Study of Phosphors for Radiation Dosimetry

نویسندگان

  • Pankaj Pathak
  • Manisha
  • Pankaj Kumar Mishra
چکیده

169 ANALYTICAL STUDY OF PHOSPHORS FOR RADIATION DOSIMETRY Pankaj Pathak1,Manisha Singh2, Pankaj Kumar Mishra3 1,2,3Department of Applied Physics, Amity School of Engineering & Technology, Amity University, Gwalior (MP) Email:[email protected] Abstract The main aim of the study is to analyse the different luminescence properties of phosphors synthesised by Combustion Synthesis (CS) Technique for Radiation Dosimetric Applications. Different electrical, optical and structural properties are seen in inorganic and organic materials in nanocrystallized form as compared to those in the bulk form. Out of these, the ones suited as phosphor host material show considerable size dependent luminescence properties when an impurity is doped in a quantum-confined structure. Pioneering studies of Thermo luminescence (TL) properties of nanostructure materials have produced encouraging results. With an objective of finding a new dosimetric material with higher sensitivity, good reproducibility, low hygroscopicity, and good response at high doses in radiotherapy and in mixed radiation fields and thereby advancing the dosimeters hence developing highly efficient materials, with high TL yield present investigation is undertaken. Activated Nano/Micro phosphor in regulated condition can be obtained by employing different Synthesis methods. Luminescent Properties exhibited by so prepared Phosphors can be tailored by impurities present, type of dopands used, molar composition of dopands and methods employed for their Synthesis, and temperature of synthesis. The materials of required properties can be synthesized by employing, hydrothermal reaction, sol-gel synthesis, micro-emulsion synthesis and mechanochemical synthesis. Key-words: Phosphors, Luminescence, Radiation Dosimetry Introduction: Thermally stimulated luminescence also termed as thermoluminescence (TL) is a powerful technique extensively used for dosimetry of ionizing radiations. TL dosimeter (TLD) materials presently in use are inorganic crystalline materials. They are in the form of chips, single crystals or microcrystalline size powder. The most popular of them are LiF: Mg, Ti, LiF: Mg, Cu, P, CaF2, Li2B4O7, CaSO4: Dy, CaF2:Dy.The TL results of the recently reported nanomaterials have revealed very imperative characteristics such as high sensitivity and saturation at very high doses .However, recent TL studies of different luminescent ceramic micro or nanomaterials showed that they have a potential application in radiation dosimetry .These materials spread over various applications

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rare earth Dy activated Li3PO4:Dy phosphors for lyoluminescence dosimetry of ionizing radiations

Rare earth Dy doped Li3PO4 phosphate based phosphors were prepared by high temperature solid state diffusion technique. The peak LL intensity initially increases with increasing mass of the sample, then tends to attain a saturation value for higher mass of the solute added to the solvent. Eaelier experiments on gamma irradiated crystals have proved that the light emission originates from the re...

متن کامل

Radioluminescence of red-emitting Eu-doped phosphors for fiberoptic dosimetry.

Fiberoptic dosimetry (FOD) technique has become an attractive method for real-time dosimetry. Al(2)O(3):Cis one of the most used radioluminescence materials for FOD due to its high efficiency but it presents the drawback of emitting in the spectral region, where spurious luminescence is also important. Optical filtering is the simplest technique to remove spurious luminescence, but is useful wh...

متن کامل

A Novel Biological Dosimetry Method for Monitoring Occupational Radiation Exposure in Diagnostic and Therapeutic Wards: From Radiation Dosimetry to Biological Effects

Background and Objective: Professional radiation workers are occupationally exposed to long-term low levels of ionizing radiation. Occupational health hazards from radiation exposure, in a large occupational segment of the population, are of special concern. Biological dosimetry can be performed in addition to physical dosimetry with the aim of individual dose assessment and biological effects....

متن کامل

Evaluation of Ferrous-Agarose-Xylenol Gel Properties in Radiation Dosimetry

Background: Over recent decades, modern protocols of external beam radioÂ‌therapy and radiation techniques such as intensity-modulated radiotherapy (IMRT) have been developed. These methods are extremely sensitive to errors in treatment delivery, so that it is essential to apply a high resolution 3D dosimetry system that has high sensitivity and is capable of measuring and verifying the complex...

متن کامل

Optical Characterization of NIPAM and PAGAT Polymer Gels for Radiation Dosimetry

Introduction The purpose of the current study was to determine optical sensitivity of N-isopropyl acrylamide NIPAM and polyacrylamide gelatin and tetrakis hydroxymethyl phosphoniun chloride (PAGAT) polymer gels for different wavelength of visible light spectrum applied in optical computed tomography method. Materials and Methods NIPAM and PAGAT polymer gels with conventional formulations used f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016