Time-varying view angle tilting with spiral readout gradients.

نویسندگان

  • Sang-Young Zho
  • Dong-Hyun Kim
چکیده

The conventional Fourier-transform-based spin-echo sequence with a view angle tilting gradient during data acquisition can correct the in-plane distortion induced by a chemical shift or B0 field inhomogeneity. However, when extended for 3D applications, alternate k-space sampling can be beneficial for reducing the lengthy scan time. As spiral trajectories have high k-space acquisition efficiency, we investigated the applicability of spiral trajectory on a spin-echo view angle tilting pulse sequence. Computer simulations and phantom and in vivo experiments were performed to validate the usage of spiral readout gradients in the presence of a view angle tilting gradient. The results show that as long as the readout time is comparable to Cartesian readout, the resulting images have similar quality.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Increasing parallel imaging performance and correcting field inhomogeneity artifact in MS-CAIPIRINHA using view angle tilting technique (CAIPI-VAT)

Purpose: To increase parallel imaging performance in multi-slice controlled aliasing in parallel imaging and to reduce field inhomogeneity artifact using view angle tilting technique. Methods: Controlled aliasing in parallel imaging (CAIPI) 2 technique makes each excited slice shift along phase encoding (PE) direction by inducing linear phase using different RF phase at each slice. Then the coi...

متن کامل

Reduction of blurring in view angle tilting MRI.

Magnetic resonance imaging (MRI) in the presence of metallic objects suffers from slice-selection errors and in-plane distortions. View angle tilting (VAT) corrects for in-plane distortions by adding a gradient on the slice-select axis during readout, but can suffer from image blurring. This work demonstrates that the major source of blurring is a slice profile modulation of the data, and propo...

متن کامل

Concomitant gradient field effects in spiral scans.

Maxwell's equations imply that imaging gradients are accompanied by higher order spatially varying fields (concomitant fields) that can cause artifacts in MR imaging. The lowest order concomitant fields depend quadratically on the imaging gradient amplitude and inversely on the static field strength. Time-varying concomitant fields that accompany the readout gradients of spiral scans cause unwa...

متن کامل

Reducing gradient imperfections for spiral magnetic resonance spectroscopic imaging.

Spiral k-space magnetic resonance spectroscopic imaging (MRSI) requires high performance from gradient hardware systems. During the readout phase, oscillating gradients are continuously played out, which can cause undesired effects. These effects on the quality of SI data are non-intuitive because of their time-varying nature. In this work we describe the effects of undesirable gradient perform...

متن کامل

Spiral readout gradients for the reduction of motion artifacts in chemical shift imaging.

A motion artifact reduction method for proton chemical shift imaging (CSI) is presented. The method uses spiral-based readout gradients for data acquisition. A characteristic of spiral-based readout gradients is that data are repeatedly sampled at the kxy origin. These data points are used to estimate and correct for motion-induced phase variations. Both phantom and in vivo spectra reconstructe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 68 4  شماره 

صفحات  -

تاریخ انتشار 2012