Effects of different torque levels on the implant-abutment interface in a conical internal connection.
نویسندگان
چکیده
The fit of the implant-abutment interface was assessed by the metallographic technique and by scanning electron microscopy (SEM), using solid abutment types at different torque levels. Forty Morse taper connections and forty solid abutments were used at different torque levels (repeated after 10 minutes) in the following groups (n = 10): 25 Ncm (group g1), 30 Ncm (group g2), 35 Ncm (group g3), and 40 Ncm (group g4). The samples were embedded in a metallographic resin, sectioned lengthwise, and polished. SEM images were used to measure the linear contacts and the fits between abutments and the internal walls of the implant. The overall mean gap and standard deviation were as follows: 9.0 ± 1.36 µm for group g1, 7.9 ± 2.81 µm for group g2, 2.0 ± 0.76 µm for group g3, and 0.3 ± 0.40 µm for group g4. A significant difference was observed in the average fit values between the groups (p < 0.05). The linear area of contact between the abutment and the implant increased as torque augmented. This study demonstrated that higher insertion torque values in a conical internal connection increase the fit (contact) of the implant-abutment interface.
منابع مشابه
Effect of Abutment Connection Type and Cyclic Loading on Removal Torque Value
Background and Aim: Maintaining the primary torque of the abutment screw is a common problem related to implant-supported restorations; a failure in this respect often leads to screw loosening. The abutment screw plays a critical role in the long-term stability of restorations. This study aimed to assess the effect of two abutment connection types with and without cyclic loading on removal torq...
متن کاملInfluence of abutment materials on the implant-abutment joint stability in internal conical connection type implant systems
PURPOSE This study evaluated the influence of abutment materials on the stability of the implant-abutment joint in internal conical connection type implant systems. MATERIALS AND METHODS Internal conical connection type implants, cement-retained abutments, and tungsten carbide-coated abutment screws were used. The abutments were fabricated with commercially pure grade 3 titanium (group T3), c...
متن کاملThe change of rotational freedom following different insertion torques in three implant systems with implant driver
STATEMENT OF PROBLEM Implant drivers are getting popular in clinical dentistry. Unlike to implant systems with external hex connection, implant drivers directly engage the implant/abutment interface. The deformation of the implant/abutment interface can be introduced while placing an implant with its implant driver in clinical situations. PURPOSE This study evaluated the change of rotational ...
متن کاملRemoval torques of conical, tapered implant abutments: the effects of anodization and reduction of surface area.
PURPOSE To examine the effects of anodization (surface coating) and reduction of internal Morse taper surface area on the reversal torque values of Straumann ITI dental implants and abutments. MATERIALS AND METHODS Eighty ITI solid screw implants were mated with corresponding 5.5-mm solid abutments. The assemblies were divided into 4 test groups of 20 specimens. All abutments were torque tigh...
متن کاملManual maximum closing torque in three implant abutment systems
Background and Aims: Diferences whithin shape and size of hand wrenches in diferent systems could affect the torque applied. Therefore, evaluation of wrenches has been emphasized. The aim of the present study was to compare the torque values of the long and short torque wrenches in different implant systems including ITI, Implantium and Nobel Biocare. Materials and Methods: In this experimenta...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Brazilian oral research
دوره 30 شماره
صفحات -
تاریخ انتشار 2016