BACKGROUND Before trans-catheter aortic valve implantation (TAVI), assessment of cardiac function and accurate measurement of the aortic root are key to determine the correct size and type of the prosthesis. The aim of this study was to compare cardiovascular magnetic resonance (CMR) and trans-thoracic echocardiography (TTE) for the assessment of aortic valve measurements and left ventricular function in high-risk elderly patients submitted to TAVI. METHODS Consecutive patients with severe aortic stenosis and contraindications for surgical aortic valve replacement were screened from April 2009 to January 2011 and imaged with TTE and CMR. RESULTS Patients who underwent both TTE and CMR (n = 49) had a mean age of 80.8 ± 4.8 years and a mean logistic EuroSCORE of 14.9 ± 9.3%. There was a good correlation between TTE and CMR in terms of annulus size (R2 = 0.48, p < 0.001), left ventricular outflow tract (LVOT) diameter (R2 = 0.62, p < 0.001) and left ventricular ejection fraction (LVEF) (R2 = 0.47, p < 0.001) and a moderate correlation in terms of aortic valve area (AVA) (R2 = 0.24, p < 0.001). CMR generally tended to report larger values than TTE for all measurements. The Bland-Altman test indicated that the 95% limits of agreement between TTE and CMR ranged from -5.6 mm to + 1.0 mm for annulus size, from -0.45 mm to + 0.25 mm for LVOT, from -0.45 mm2 to + 0.25 mm2 for AVA and from -29.2% to 13.2% for LVEF. CONCLUSIONS In elderly patients candidates to TAVI, CMR represents a viable complement to transthoracic echocardiography.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative analysis of paravalvular leak of transcatheter aortic valves using cardiac MR

Background There is now extensive registry and clinical trial data demonstrating an increased incidence of paravalvular leak following transcatheter aortic valve implantation (TAVI) when compared with open aortic valve replacement (AVR). Despite recent improvements in both hardware and software, echocardiographic measurement of aortic regurgitation (AR) largely remains qualitative in nature. Ca...

متن کامل

Prevalence and Prognostic Significance of Right Ventricular Systolic Dysfunction in Patients Undergoing Transcatheter Aortic Valve Implantation.

BACKGROUND Cardiovascular magnetic resonance (CMR) can provide important structural information in patients undergoing transcatheter aortic valve implantation. Although CMR is considered the standard of reference for measuring ventricular volumes and mass, the relationship between CMR findings of right ventricular (RV) function and outcomes after transcatheter aortic valve implantation has not ...

متن کامل

Multimodality assessment of aortic stenosis severity in Transcatheter Aortic Valve Implantation (TAVI): comparison between cardiovascular magnetic resonance, transesophageal and transthoracic echocardiography

Multimodality assessment of aortic stenosis severity in Transcatheter Aortic Valve Implantation (TAVI): comparison between cardiovascular magnetic resonance, transesophageal and transthoracic echocardiography Andrew Jabbour, Tevfik F Ismail, Ali Vazir, Isabelle Roussin, Ankur Gulati, Francisco Alpendurada, Sameer Zaman, Oluwatosin Sotubo, Saman S Zaman, Benjamin Hewins, Simon Davies, Sanjay K P...

متن کامل

Quantitative analysis of post-TAVI aortic regurgitation with cardiovascular magnetic resonance and the relationship to transthoracic echocardiography

Background Transcatheter Aortic Valve Implantation (TAVI) is increasingly used to treat patients with severe aortic stenosis at high surgical risk. The severity of post-implantation valvular or paravalvular regurgitation has been shown to adversely affect patient outcome. The aim of the study was to assess the prevalence and severity of aortic regurgitation (AR) at 6 months post-TAVI using card...

متن کامل

Assessment of cognitive functions and quality of life in patients scheduled for transcatheter aortic valve implantation: a pilot study

Corresponding author: Katarzyna Olszewska MD, PhD, 2 Department of Cardiology and Cardiovascular Interventions, University Hospital, 17 Kopernika St, 31-501 Krakow, Poland, phone: +48 12 424 71 81, e-mail: [email protected] Received: 25.06.2017, accepted: 31.08.2017. Assessment of cognitive functions and quality of life in patients scheduled for transcatheter aortic valve implantation:...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2011