Measurement of 90Sr in Reactor Wastes by Cerenkov Counting of 9oY
نویسنده
چکیده
Determination of 90Sr in low-level radioactive wastes (LLW) from reactors is difficult because of the presence of so many other radionuclides in samples of interest. This problem was dealt with by radiochemical separation of strontium followed by yttrium separation and Cerenkov counting of the high-energy B-particle emissions of 9oY in order to quantitate s”Sr. Separation of this important nuchde in low-level waste samples was by solvent extraction using tri-n-butyl phosphate. Since most beta emitters in LLW from commercial nuclear power facilities are below about 1 MeV, Cerenkov counting with a high-discriminator setting provided accurate quantitation without interference of potential contaminants which were either removed by separation or discriminated against by the counting procedure. A tracer of 8SSr was used and the radiochemical yield was 59.6 + 1.9%; the lower limit of detection was found to be 1.48 pCi/g based on a 10 g sample and a 20-min counting time.
منابع مشابه
Measurement of 90sr in aqueous samples using liquid scintillation counting with full spectrum DPM method.
90Sr activity was measured with the full spectrum DPM (FS-DPM) counting method after plotting the quench correction curves of 90Sr and 90Y, and the FS-DPM method was applied to determine the 90Sr in liquid waste samples. The optimum regions of 90Sr and 90Y were set for measuring 90Sr with the dual label DPM (DL-DPM) method. The direct measurement of purified 90Sr with spectrum unfolding techniq...
متن کاملRapid on-site radionuclide screening of aqueous waste streams using dip-stick technologies and liquid scintillation counting
This paper describes an early-stage evaluation of a purpose-designed extraction/detection system that can be deployed by non-specialists either on-site or as part of a mobile laboratory. The system comprises three main components; (1) an optimised compact extraction system for recovery of radionuclides from the waste form; (2) an extraction test strip designed to recover the radionuclides from ...
متن کاملIodine analysis of biological samples by neutron activation of 127-I, with scintillation counting of Cerenkov radiation.
To measure the small amounts of iodine in tissues, organelles, and subfractions it is necessary to use very sensitive and specific analytical methods. Neutron activation analysis meets these criteria; the measurement of lZ81 after irradiation of the naturally occurring isotope, 1271, has a sensitivity of about 0.08 nanogram (12). However, neutron activation analysis has the disadvantage of requ...
متن کاملSimultaneous measurement of 89Sr and 90Sr in aqueous samples by liquid scintillation counting using the spectrum unfolding method.
Two radiostrontium isotopes, 89Sr and 90Sr, were measured simultaneously by liquid scintillation counter coupling with a full spectrum DPM counting protocol. Strontium was separated from the aqueous media by extraction chromatography using Sr-spec resin. Individual count rates were evaluated from quench correlation curves for 89Sr and 90Sr related with SIS and tSIE quench indicators. The method...
متن کاملSynthesis and Characterization of γ-MnO2-AgA Zeolite Nanocomposite and its Application for the Removal of Radioactive Strontium-90 (90Sr)
In this scientific research, for the first time, the removal of radioactive strontium-90 (90Sr) by γ-MnO2-AgA zeolite as a novel nanocomposite adsorbent was accomplished under different conditions such as pH, temperature, adsorbent amount and the contact time that are examined from drinking water of Ramsar city and monitored via Ultra Low-Level Liquid Scintillation Counting (LSC) technique. Pri...
متن کامل