A Comparison between Voltage and Reactive Power Feedback Schemes of DFIGs for Inter-Area Oscillation Damping Control

نویسندگان

  • Kai Liao
  • Yao Wang
چکیده

Reactive power modulation of wind power plants is an effective way to damp inter-area oscillation in wind power penetrated power systems. For doubly fed induction generator (DFIG) based wind farms, there are two different ways to achieve reactive power modulation: one is via reactive power feedback control, and the other method is via voltage feedback control. While both of the control schemes are feasible, their effectiveness may differ, and there has not been a systematic comparison between them. This paper investigates the differences between these two feedback schemes for inter-area oscillation damping control. The principles of utilizing DFIG for damping control is introduced at first. Then, analytical techniques including the frequency domain analysis, μ-analysis and time domain analysis are used to systematically study the performance of the two control schemes against inter-area oscillation. The robustness of the control schemes with respect to the variety of system operation points is also studied. The results from this paper can provide an insight into the understatement of DFIG reactive modulation against oscillation and guidance for controller design.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Delay-Scheduled Controllers for Inter-Area Oscillations Considering Time Delays

Unlike the existing views that was introduced the existence of delay caused by the transmission of wide area measurement system data (WAMS) into the controllers input of the power oscilation damping (POD) by communication networks as a reason for poor performance of the POD controllers. This paper shows that the presence of time delay in the feedback loop may improve the performance of a POD co...

متن کامل

Coordinated Control of Doubley Fed Induction Generator Virtual Inertia and Power System Oscillation Damping Using Fuzzy Logic

Doubly-fed induction generator (DFIG) based wind turbines with traditional maximum power point tracking (MPPT) control provide no inertia response under system frequency events. Recently, the DFIG wind turbines have been equipped with virtual inertia controller (VIC) for supporting power system frequency stability. However, the conventional VICs with fixed gain have negative effects on inter-ar...

متن کامل

Design Supplementary Controller Based on Stabilizing Effect of Delay for Damping Inter Area Oscillations in a Power System

The delay associated with signal transmission through the wide-area measurement system reduces the functionality of the power oscillation damping control system. One of the important issues is the poor operation of the supplementary controller against delay existence, which limits the efficiency of damping of ancillary equipment, such as SVCs in a power system. This paper as a solution proposes...

متن کامل

Global Power System Control Using a Unified Power Flow Controller

This paper explores the use of a Unified Power Flow Controller (UPFC) for global power system control. Coordinated control schemes are assigned to the UPFC, Power System Stabilizer (PSS) and generator excitation to maintain transient stability and voltage stability following a disturbance. The extension to use of UPFC in damping inter-area oscillation is also considered. Under the proposed coor...

متن کامل

The Dynamic Impact of Large Wind Farms on Power System Stability

As the installed capacity of wind power increases across the world, its impact on power systems is becoming more important. To ensure the reliable operation of a power system which is significantly fed by wind power, the dynamics of the system must be understood. The purpose of this study is to analyse the dynamic impact of large-scale wind farms on the stability of a power grid, and to investi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017