Total skin electron therapy: a modified technique for small room linear accelerator.

نویسندگان

  • Tarek Shouman
  • Zeinab El-Taher
چکیده

OBJECTIVE Development of a technique for treating whole-body skin using linear accelerator with electron beam energy of 6-MeV at a short treatment distance. MATERIAL AND METHODS The 6 MeV high dose rate total skin electron irradiation mode on a linear accelerator was used. Beam profiles and percentage depth doses in the patient plane were measured for different beam angulations. RESULTS At a treatment distance (SSD) of 292 cm and using acrylic scatterer-degrader 4mm thick, the beam penetration was calculated so that the 80% dose lied at 1.6 cm for the single beam and only 6 mm for the clinical beam. A uniform vertical profile was obtained by using 3 beams for each treatment position with gantry angles of 700, 900 and 1100. CONCLUSIONS We could implement a modified stanford technique for total skin electron beam irradiation at a short treatment distance. Using an acrylic scatterer-degrader and three beam angulations we could produce a uniform beam in the treatment plane.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Total skin electron therapy (TSET): Monte Carlo Simulation and implementation

Introduction: Total skin electron irradiation technique is used in treatment of the mycosis fungoid. The implementation of this technique requires non-standard measurements and complex dosimetry methods. Operating procedures for total skin electron irradiation and its dosimetry vary in different radiation therapy centers in the world. In this article, validation of TSET techniq...

متن کامل

Rotational total skin electron irradiation with a linear accelerator

The rotational total skin electron irradiation (RTSEI) technique at our institution has undergone several developments over the past few years. Replacement of the formerly used linear accelerator has prompted many modifications to the previous technique. With the current technique, the patient is treated with a single large field while standing on a rotating platform, at a source-to-surface dis...

متن کامل

محاسبه میزان دز پرتوهای ترمزی ناشی از الکترون ها در پرتو درمانی با الکترون در بیمارستان آیت ا...خوانساری اراک

During the radiation therapy with electron beam, due to electron interaction and scattering from structures of the head of the medical linear accelerator, unwanted photons are produced. The main contribution of the photon contamination is resulted from the various components of the medical linear accelerator on the way of the high energy electron beam, and few percent is due to the interaction ...

متن کامل

Localization of electron virtual SSD in a Siemens-Primus linear accelerator: Comparison of measurements with Monte Carlo simulation

Introduction: Because of importance of impact of the Source to Surface Distance (SSD) in determining of monitor unit for electron-therapy, it is essential to know the Virtual Source Position (VSP) for electron beam for a linear therapeutic accelerator for each energy and field size. , especially using the Khan method (photo distance squared method) And compare the results with...

متن کامل

Estimation of Secondary Skin Cancer Risk Due To Electron Contamination in 18-MV LINAC-Based Prostate Radiotherapy

Introduction Accurate estimation of the skin-absorbed dose in external radiation therapy is essential to estimating the probability of secondary carcinogenesis induction Materials and Methods Electron contamination in prostate radiotherapy was investigated using the Monte Carlo (MC) code calculation. In addition, field size dependence of the skin dose was assessed. Excess cancer risk induced by...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the Egyptian National Cancer Institute

دوره 16 4  شماره 

صفحات  -

تاریخ انتشار 2004