Improving the Response of Copper(II) Selective PVC Membrane Electrode by Modification of N2S2 Donor Ligand.
نویسندگان
چکیده
S,S'-bis(2-aminophenyl)ethanebis(thioate), (APhET), is reported as N2S2 ligand which form chelate with copper of high stability as compared to the other metals. Two modification of APhET, simpler 1,2-di-(o-aminophenylthio)ethane (DAPhTE), and the complex one 1,2-di-(o-salicylaldiminophenylthio)ethane (SAPhTE), were examined as the active material for copper(II) ion selective PVC membrane electrodes, and observed results are correlated. The obtained results with DAPhTE based electrodes show that only coordination abilities of ligand are insufficient for preparing the efficient membrane material. On the other hand, the results that are achieved with electrodes based on SAPhTE actuate interaction of ligand with polymer membrane matrix and necessity of ionophore immobilization in membrane. Optimized SAPhTE based membrane electrode has a linear range down to 10-6 mol L-1, with slope of 27.0 mV per decade, very rapid response time (under 5 seconds) and detection limit of 5.1 × 10-7 mol L-1. Such electrode is suitable for determination of copper(II) in analytical measurements by direct potentiometry and in potentiometric titrations, within pH between 2 and 7. The electrode is selective for copper(II) ions over a large number of metal ions, with the exception on Hg2+ ion when is present in concentrations above 2 × 10-5 mol L-1.
منابع مشابه
(1E,2E) -bis (2-aminophenyl) N'1,N'2-dihydroxyethane bis (imidothioate) as a neutral carrier in ion-selective electrode for Ni(II) and it computational studies
A PVC membrane Ni(II) ion selective electrode has been constructed using (1E,2E)-bis(2-aminophenyl)N'1,N'2-dihydroxyethanebis as membrane carrier. The electrode exhibited a goodpotentiometric response for Ni(II) over a wide concentration range 1.0×10-4 to 1.0×10-1M with aslope of 29.4±0.5 mV/decade a and a working pH range of 6.5-9.0. It had a fast response time of≤20s. The best performance was...
متن کاملNew Coated Graphite Potentiometric Sensor for Selective Determination of Copper (II) Ions
A highly selective copper (II) coated graphite sensor was prepared by 1,13-bis(8-quinolyl)- 1,4,7,10,13-pentaoxatridecane (kryptofix 5) as a supramolecule ionophore into plasticized polyvinyl chloride (PVC) membrane. The best response characteristic was observed using the membrane composition of PVC = 30.0 mg, dioctyl sebacate (DOS) = 63.5 mg, palmitic acid (PA) = 3.0 mg and kryptofix 5 = 3.5 m...
متن کاملDesign and Fabrication of PVC Membrane Electrode Based on Netural Ligand (E)-N'-(1-(2-Hydroxyphenyl)Ethylidene)Benzohydrazi for Teramadol hydrochloride Measurement in Drugs and Biological Fluids
Here, a simple, quick, Low cost and sensitive Potentiometric method is described for tramadol hydrochloride measurement using .PVC membrane electrode based on neutral ligand (E)-N'-(1-(2-hydroxyphenyl)ethylidene)benzohydrazid. Besides, effect of various parameters like ionic additives, membrane solvent and pH on the Potentiometric response of the electrode are investigated. The best electrode p...
متن کاملIodide selective membrane electrode based on copper (Π)-bis-Nphenilsalicyldenaminato complex
An iodide ion-selective PVC membrane sensor based on copper (Π)-bis-Nphenilsalicyldenaminatocomplex as a novel sensing material is successfully developed. Theelectrode showed a good selectivity for iodide ion with respect to common inorganic anions. Thesensor exhibited a good linear response with slope of _58.6 ± 0.4 mV per decade over theconcentration range of 5.0 × 10-6 to 1.0 × 10-1 mol L-1,...
متن کاملFe (II) Ion-Selective Membrane Electrode based onTetra-Phenyl Porphyrin in PVC Matrix
Fe2+ ion-selective membrane sensor has been fabricated from polyvinyl chloride (PVC) matrixmembrane containing neutral carrier tetra phenyl porphyrin (TPP) ionophore. The addition ofsodium tetraphenylborate (NaTPB) and the plasticizer DBP has been found to substantiallyimprove the performance of the sensor. The best performance was obtained with the sensor havinga membrane of composition of TPP...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta chimica Slovenica
دوره 57 2 شماره
صفحات -
تاریخ انتشار 2010