Exploring the role of the sampler housing in limiting uptake of semivolatile organic compounds in passive air samplers.

نویسندگان

  • Xianming Zhang
  • Michelle Hoang
  • Ying D Lei
  • Frank Wania
چکیده

Passive air samplers (PASs) are simple, versatile devices that are increasingly used to determine the concentrations of semivolatile organic compounds (SVOCs) in the atmosphere. Using PAS and interpreting PAS-derived data with confidence requires a detailed understanding of the factors that control the uptake kinetics. A number of experiments were aimed at clarifying the role that the housing has in limiting the uptake of SVOCs in a PAS. Specifically, we quantified the gradient in the amount of polychlorinated biphenyls (PCBs) accumulated in XAD-filled mesh cylinders with increasing distance from the PAS housing's opening. That gradient was non-existent in an artificially ventilated housing (i.e. different segments of a cylinder contained the same amount of PCBs), minor during outdoor deployments (i.e. the bottom third of the cylinder sampled approximately 20% more PCBs than the top third), and strong during indoor deployments (i.e. the bottom third of the cylinder sampled twice the amount sampled by the top third). This is consistent with the thickness of the air boundary layer surrounding the XAD-resin increasing with increasing distance from the housing's opening and decreasing with increasing air turbulence. An experiment with housings absorbing different amounts of sunlight revealed that heat-induced convection has a minor effect on the gradient within the mesh cylinder and on the total amount of accumulated PCB. Similarly, this gradient and the total amount sorbed was also not influenced by the number of XAD-filled mesh cylinders placed within a housing as long as they were deployed outdoors. However, if four mesh cylinders were placed in one housing in a calm indoor setting, the top third of the mesh cylinders was notably starved of PCBs, suggestive of an air concentration gradient within the sampler housing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sampling medium side resistance to uptake of semivolatile organic compounds in passive air samplers.

Current theory of the uptake of semivolatile organic compounds in passive air samplers (PAS) assumes uniform chemical distribution and no kinetic resistance within the passive sampling media (PSM) such as polystyrene-divinylbenzene resin (XAD) and polyurethane foam (PUF). However, these assumptions have not been tested experimentally and are challenged by some recently reported observations. To...

متن کامل

SAMPLING, CLEAN-UP AND SEPARATION Evaluation of performance reference compounds in PUF passive air samplers at different wind speeds

ORGANOHALOGEN COMPOUNDS – Volume 66 (2004) 138 Introduction Polyurethane foam (PUF) samplers are being used in an increasing number of studies to passively sample semivolatile organic compounds (SOCs) in the atmosphere (e.g. 1, ). However, recent research shows that the uptake and loss kinetics of passive air samplers is influenced by changes in wind speed . According to theory, the rate of che...

متن کامل

Influence of sampler configuration on the uptake kinetics of a passive air sampler.

Passive air samplers (PAS) are simple and cost-effective tools to monitor semivolatile organic compounds in air. Chemical uptake occurs by molecular diffusion from ambient air to a passive sampling medium (PSM). Previous calibration studies indicate that even for the same type of PAS, passive air sampling rates (R, m(3)(air)/d) can be highly variable due to the influence of a number of factors....

متن کامل

Passive sampling for volatile organic compounds in indoor air-controlled laboratory comparison of four sampler types.

This article describes laboratory testing of four passive diffusive samplers for assessing indoor air concentrations of volatile organic compounds (VOCs), including SKC Ultra II, Radiello®, Waterloo Membrane Sampler (WMS) and Automated Thermal Desorption (ATD) tubes with two different sorbents (Tenax TA and Carbopack B). The testing included 10 VOCs (including chlorinated ethenes, ethanes, and ...

متن کامل

Characterization and Application of Passive Samplers for Monitoring of Pesticides in Water.

Five different water passive samplers were calibrated under laboratory conditions for measurement of 124 legacy and current used pesticides. This study provides a protocol for the passive sampler preparation, calibration, extraction method and instrumental analysis. Sampling rates (RS) and passive sampler-water partition coefficients (KPW) were calculated for silicone rubber, polar organic chem...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Environmental science. Processes & impacts

دوره 17 12  شماره 

صفحات  -

تاریخ انتشار 2015