The MOVE-trial: Monocryl® vs. Vicryl Rapide™ for skin repair in mediolateral episiotomies: a randomized controlled trial

نویسندگان

  • Roeland Odijk
  • Bernadette Hennipman
  • Melek Rousian
  • Khadija Madani
  • Marja Dijksterhuis
  • Jan Willem de Leeuw
  • Arjan van Hof
چکیده

BACKGROUND Previous studies have shown that complaints after episiotomy repair depend on the method and material used for repair. The objective of our study was to determine which of two frequently used suture materials, Monocryl® (poliglecaprone 25) and Vicryl Rapide™ (polyglactin 910), is superior for intracutaneous closure of the skin in mediolateral episiotomies. METHODS In a randomized controlled trial performed in a teaching hospital in the Netherlands between 2010 and 2013 250 primiparous women with uncomplicated mediolateral episiotomies were randomly allocated to intracutaneous skin closure with either Monocryl® or Vicryl Rapide™. All other layers were sutured with Vicryl 2-0 and Vicryl 0 in both groups. Pain scores and complications were documented using questionnaires during the first three months post partum. The primary outcome was pain 10 days after delivery in sitting position established by Visual Analogous Scale (VAS). Secondary outcomes were pain scores at different time points and reported complications such as infections, dehiscence and dyspareunia one day, 10 days, six weeks and three months after delivery. RESULTS Of 250 allocated women 54% returned questionnaires. No statistical difference was found between both groups for the primary outcome (VAS 2,8 (95% CI 2,18-3,44) vs. VAS 2,5 (95% CI 2,00-2,98), p = 0,43). With regard to secondary outcomes only self-reported dehiscence was significantly different, favouring Monocryl® (10% vs. 25%, p = 0.016). CONCLUSIONS Use of Monocryl® 3-0 and Vicryl Rapide™ 3-0 for intracutaneous closure of the skin after mediolateral episiotomy leads to equal pain scores ten days after delivery and therefore both materials may be considered for this use. Monocryl® 3-0 might be favourable over Vicryl Rapide™ 3-0 due to less self-reported dehiscence after intracutaneous closure of the skin in mediolateral episiotomies. TRIAL REGISTRATION The trial was retrospectively registered under trial nr. ISRCTN29869308 on 20-04-2016.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی و مقایسه نتایج حاصل از ترمیم اپی زیاتومی با نخ کات گوت کرومیک ( بیولوژیک) و نخ راپیدواکریل در زنان مراجعه کننده به یکی از بیمارستانهای دانشگاههای علوم پزشکی ایران 1373

  The main aim of this double blind randomized clinical trial was to determine and compare the results and complications of using Catgut chromic (biologic ) and Vicryl rapide (sytlthetic) as a suture material in episitomy   repair. 46 primiparus women were entered in this study randomly. Episiotomy of 2/ women were rep aired by   Vicryl rapide and 25 by Catgut chromic. These two groups were mat...

متن کامل

A prospective randomized comparative study of vicryl rapide versus chromic catgut for episiotomy repair.

BACKGROUND AND OBJECTIVES A significant number of women experience perineal trauma following vaginal deliveries and they require stitches. This may result in perineal pain, dyspareunia and faulty healing. The type of suture material which is used, will influence these factors. This study was conducted to compare the impact of two absorbable suture materials which were used for episiotomy repair...

متن کامل

Material and type of suturing of perineal muscles used in episiotomy repair in Europe

Episiotomy, the incision of the perineum during the last part of the second stage of labour or delivery is still considered a controversial procedure. Long-term complications after episiotomy repair are common. A large proportion of women suffer short-term perineal pain and up to 20% have longer-term problems (e.g. dyspareunia).1 Other complications involve the removal of suture material, exten...

متن کامل

Two-month longitudinal study of mechanical properties of absorbable sutures used in orthopedic surgery

BACKGROUND This is the first study assessing the properties of large-diameter degradable sutures relevant for orthopedic applications over the course of in vitro incubation for 2 months. The data we present here provide guidance to the orthopedic surgeon in predicting the long-term performance of suture materials used everyday in surgical practice. METHODS Five different absorbable (Vicryl, M...

متن کامل

A comparison of cosmetic outcomes of lacerations on the extremities and trunk using absorbable versus nonabsorbable sutures.

OBJECTIVES The primary objective was to compare the cosmetic outcomes of traumatic trunk and extremity lacerations repaired using absorbable versus nonabsorbable sutures. The secondary objective was to compare complication rates between the two groups. METHODS This was a randomized controlled trial comparing wounds repaired with Vicryl Rapide and Prolene sutures. Pediatric and adult patients ...