Effect of wind on the chemical uptake kinetics of a passive air sampler.

نویسندگان

  • Xianming Zhang
  • Trevor N Brown
  • Amer Ansari
  • Beom Yeun
  • Ken Kitaoka
  • Akira Kondo
  • Ying D Lei
  • Frank Wania
چکیده

Passive air samplers (PASs) operate in different types of environment under various wind conditions, which may affect sampling rates and thus introduce uncertainty to PAS-derived air concentrations. To quantify the effect of wind speed and angle on the uptake in cylindrical PASs using XAD-resin as the sampling medium, we measured the uptake kinetics of polychlorinated biphenyls (PCBs) in XAD and of water in silica-gel, both under quasi wind-still condition and with lab-generated wind blowing toward the PASs at various speeds and angles. Passive sampling rates (PSRs) of PCBs under laboratory generated windy conditions were approximately 3-4 times higher than under wind-still indoor conditions. The rate of water uptake by silica-gel increased with wind speed, following a logarithmic function so that PSRs are more strongly influenced at lower wind speed. PSRs of both PCBs and water varied little with wind angle, which is consistent with computational fluid dynamic simulations showing that different angles of wind incidence cause only minor variations of air velocities within the cylindrical sampler housing. Because modifications of the design of the cylindrical PAS were not successful in eliminating the wind speed dependence of PSRs at low wind levels, indoor and outdoor deployments require different sets of PSRs. The effect of wind speed and angle on the PSRs of the cylindrical PAS are much smaller than what has been reported for the double-bowl polyurethane foam PAS. PSRs of the cylindrical XAD-PAS therefore tend to vary much less between sampling sites exposed to different wind conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of sampler configuration on the uptake kinetics of a passive air sampler.

Passive air samplers (PAS) are simple and cost-effective tools to monitor semivolatile organic compounds in air. Chemical uptake occurs by molecular diffusion from ambient air to a passive sampling medium (PSM). Previous calibration studies indicate that even for the same type of PAS, passive air sampling rates (R, m(3)(air)/d) can be highly variable due to the influence of a number of factors....

متن کامل

SAMPLING, CLEAN-UP AND SEPARATION Evaluation of performance reference compounds in PUF passive air samplers at different wind speeds

ORGANOHALOGEN COMPOUNDS – Volume 66 (2004) 138 Introduction Polyurethane foam (PUF) samplers are being used in an increasing number of studies to passively sample semivolatile organic compounds (SOCs) in the atmosphere (e.g. 1, ). However, recent research shows that the uptake and loss kinetics of passive air samplers is influenced by changes in wind speed . According to theory, the rate of che...

متن کامل

Evaluating the PAS-SIM model using a passive air sampler calibration study for pesticides.

The main objective of this study was to evaluate the performance of a model for simulating the uptake of various pesticides on passive air samplers (PAS). From 2006-2007 a series of PAS using XAD-resin were deployed at Egbert, a rural agricultural site in southern Ontario, Canada, to measure the uptake of pesticides for time periods ranging from two months to one year. A continuous increase in ...

متن کامل

Performance Characteristics of Personal Samplers in Still and Moving Air

Personal samplers or in general blunt body samplers are widely used in occupational hygiene for collecting air contaminants in the work environments. This work is part of an ongoing research into the performance evaluation of personal samplers, particularly in terms of their aerodynamic properties. Velocity profiles have been measured around and within typical cylindrical sampling devices, ...

متن کامل

Characterization of polymer coated glass as a passive air sampler for persistent organic pollutants.

The use of thin-film polymer-coated glass surfaces or POGs as passive air samplers was investigated during an uptake experiment in an indoor environment with high levels of gas-phase polychlorinated biphenyls (PCBs). POGs consisted of a micron thick layer of ethylene vinyl acetate (EVA) coated onto glass cylinders. The uptake was initially linear with time and governed by the air-side mass tran...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Environmental science & technology

دوره 47 14  شماره 

صفحات  -

تاریخ انتشار 2013