A comparison of two automated methods for the detection and identification of red blood cell alloantibodies.

نویسندگان

  • Giovanni Garozzo
  • Vincenzo Licitra
  • Rosario Criscione
  • Nunzio Comitini
  • Chiara Noto
  • Rosario Lomagno
  • Daniela Ruta
  • Giovanni Spadola
  • Valeria Zago
  • Pietro Bonomo
چکیده

BACKGROUND The aim of this study was to compare the routine use of two automated systems (OrthoAutoVue Innova, microcolumn, and Immucor Galileo, solid phase) for the screening and identification of irregular red blood cell alloantibodies in samples, analysed in our Transfusion Service during 6 months of normal activity. The study focused particularly on an evaluation of the repeatability of the screening tests, the identification of antibody specificities and the identification of antibodies in samples showing discordant results. MATERIALS AND METHODS Overall 2,229 samples from potential blood donors (A), multiply transfused patients with blood disorders (DH), potential transfusion recipients (TS), and external cases (E) were studied. The protocols were carried out according to the manufacturers recommendations. RESULTS The screening tests detected 78 samples that were positive with both systems, while 18 were positive only with Immucor and 11 only with Ortho (thus, overall, Immucor detected 96 positive samples and Ortho 89 positive samples). The use of the respective identification panels enabled us to identify the antibodies in 65 samples with Immucor and in 61 samples with the Ortho system; 74 antibodies were identified with Immucor (55 with a single specificity and 19 with mixed specificities) and 68 antibodies with Ortho (51 and 17, respectively). In the remaining cases (31 samples for Immucor and 28 for Ortho), the antibody specificity was not identified. The two systems were found to be essentially similar. The Immucor system revealed a greater number of antibodies, mainly because of its greater sensitivity at detecting anti-D antibodies. CONCLUSIONS Both systems showed a repeatability of over 85%, demonstrating that automation of immunohaematological tests is advantageous. The specificity of the antibody was identified in 68% of the samples. Furthermore, using the two systems led to the identification of ten new antibodies (6 anti-D, 2 anti-E, 1 anti Le(a), and 1 anti-Vel), which would not have been detected had only one of the two methods been used.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prevalence of Alloantibodies and Autoantibodies in Transfusion Dependent Thalassemia Patients

Background: The development of anti-red blood cell alloantibodies remains a major problem in transfusion of blood in thalassemia major patients. Also, Autoantibodies can result in clinical hemolysis and difficulty in cross-matching blood. We studied the frequency of red blood cell alloimmunization and autoimmunization among thalassemia patients who received regular transfusions in Ilam province...

متن کامل

Red Blood Cells Alloimmunization and Autoimmunization in Multi-transfused Thalassemia Patients in South of Iran

Background: Recurrent blood transfusion is a common treatment in patients with thalassemia. The development of antibodies against red blood cell (RBC) antigens complicates RBC cross-matching, enhances the in vivo destruction of transfused cells, accelerates tissue iron overloading, delays the provision of safe transfusion, and reduces health-related quality of life. Materials and Methods: In t...

متن کامل

Prevalence and specificities of red cell alloantibodies in transfusion-dependent beta thalassemia patients in Yazd

Abstract Background Multiple transfusions in thalassemia patients may lead to antibody production against blood group antigens and hemolytic transfusion reaction might occur. In this study, antibody screening test was performed by tube and gel methods to determine the prevalence and specificity of alloantibodies in thalassemia patients. Materials and Methods In this cross-sectional study, overa...

متن کامل

Frequency and Risk Factors of Red Blood Cell Alloimmunization in Thalassemia Major Patients in Markazi province

Background: Thalassemia is one of the most common genetic disorders throughout the world. Blood transfusion plays an important role in the treatment of thalassemia but it leads to numerous complications such as iron overload and alloimmunization. This study evaluated the frequency and risk factors associated with alloimmunization in thalassemia major patients living in Markazi province, Iran. ...

متن کامل

Red Blood Cell Alloimmunization in Patients with Thalassemia Major and Intermediate in Southwest Iran

Background: Transfusion is the mainstay treatment of patients with thalassemia major and occasionally in thalassemia intermediate. Alloimmunization is an unwanted side effect of blood transfusion. The present study intended to determine the frequency of alloimmunization in patients with β- thalassemia major and thalassemia intermediate in Southwest Iran. Patients and Methods: This was a cross-...

متن کامل

Identification of First Patient with Rh null Phenotype in Southeast Iran

Background and Aims: Rhnull, with an estimated incidence of one per 6,000,000 individuals, is an extremely rare disorder with an autosomal recessive pattern of inheritance that is more common in societies with a high rate of consanguinity. Materials and Methods: In this study, we report the first case with Rhnull, a blood group phenotype in southeast Iran, which was diagnosed during pretransf...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Blood transfusion = Trasfusione del sangue

دوره 5 1  شماره 

صفحات  -

تاریخ انتشار 2007