Evaluation of New Digital Detectors for High Resolution Radiography

نویسندگان

  • V. Kaftandjian
  • C. Luc
  • B. Munier
چکیده

Abstract: In the actual study, two digital detectors were investigated : an amorphous silicon flat panel and a TDI multilinear detector. The contrast and IQI sensitivity was selected to compare flat panel and film radiography. The influence of X-ray conditions was assessed in the case of flat panel. Spatial resolution of both digital detectors was assessed by adapting the geometrical magnification for each, in order that their equivalent pixel size was comparable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigating the capability of plastic scintillation detectors in design of a muon radiography system by Geant4 code

Imaging and identifying materials with high atomic numbers and densities, especially radioactive materials, is one of the issues that have been especially considered in recent years. Due to some limitations in conventional and old imaging techniques, finding an alternative method is very important. The cosmic muons with an infinite source are one of the sources that have been recently studied f...

متن کامل

Image quality assessment in digital radiography systems- A Pehamed FLUORAD A+D phantom study

Introduction: The use of digital radiography systems has become more common all around the world. Ideal situation in radiography is to maximize the image quality while minimizing the patient dose. The purpose of this study was to compare image quality and radiation dose in different digital radiography systems. Materials and Methods: Images of Pehamed FLUORAD ...

متن کامل

Quality comparison of direct digital panoramic radiography and computed radiography panoramic

BACKGROUND AND AIM: Digital panoramic X-ray images can be captured using photostimulable phosphors or solid-state detectors (i.e. charge-coupled devices and Flat-Panels). The first category is defined as computed radiography (CR) or semi-direct radiography. The second technology that uses solid-state detectors is known as direct digital radiography (DDR). Both of these technologies have their o...

متن کامل

Patient effective dose evaluation for chest X-ray examination in three digital radiography centers

Background: The radiation doses resulting from diagnostic X-ray examinations are routinely measured in terms of entrance surface dose (ESD) and effective dose (ED). In this study, for the purpose of radiation protection, the radiation doses received from Digital chest X-ray examination were evaluated in terms of ESD and ED. Material and Methods: The ED was calculated by using the MCNP ...

متن کامل

ارزیابی تطبیقی کارایی ساختار فراداده نظام‌های شناسگر دیجیتالی

The main solution to the problems of persistency and uniqueness in identification of digital objects in a web environment is provided by using digital identifiers instead of URL. The main basis of this solution is resolution mechanism that is used in digital identifier systems. Resolution is the use of indirect names instead of URLs; what worked for the DNS (Domain Name System) in stabilizing i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004