Assay instrument-dependent matrix effects in standardization of cholesterol measurements.

نویسندگان

  • P P Waymack
  • W G Miller
  • G L Myers
چکیده

Human serum-based frozen reference materials have been used by the Centers for Disease Control and Prevention (CDC)-National Heart, Lung and Blood Institute Lipid Standardization Program to improve the precision and accuracy of blood cholesterol measurements. Occasionally, laboratories in the program have had problems obtaining results for patients' fresh serum samples equivalent to those obtained with frozen CDC standardization pools. This incompatibility of sample, reagent, instrument, and assay characteristics has been labeled broadly as a "matrix effect," which usually is attributed to unknown characteristics of the processed pool material. In this study we showed that a large negative bias obtained with CDC pools was attributable to use of the sample blank mode on the Cobas-Bio analyzer. However, under the same conditions, fresh patients' serum samples were analyzed accurately. The use of a blank absorbance immediately after mixing sample and reagents (the "autoblank" mode) allowed the instrument to accurately analyze both fresh serum samples and CDC standardization pools and thus allowed the documentation of traceability of the cholesterol measurements to the National Reference System for Cholesterol.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurements for 8 common analytes in native sera identify inadequate standardization among 6 routine laboratory assays.

BACKGROUND External quality assessment (EQA) with commutable samples is essential for assessing the quality of assays performed by laboratories, particularly when the emphasis is on their standardization status and interchangeability of results. METHODS We used a panel of 20 fresh-frozen single-donation serum samples to assess assays for the measurement of creatinine, glucose, phosphate, uric...

متن کامل

Survey of total error of precipitation and homogeneous HDL-cholesterol methods and simultaneous evaluation of lyophilized saccharose-containing candidate reference materials for HDL-cholesterol.

BACKGROUND Standardization of HDL-cholesterol is needed for risk assessment. We assessed for the first time the accuracy of HDL-cholesterol testing in The Netherlands and evaluated 11 candidate reference materials (CRMs). METHODS The total error (TE) of HDL-cholesterol measurements was assessed in native human sera by 25 Dutch clinical chemistry laboratories. Concomitantly, the suitability of...

متن کامل

Study of Antimetastatic Effect of Genistein Through Inhibition of Expression of Matrix Metalloproteinase in A-549 Cell Line

The lung cancer is one of the most dangerous cancers and is also the leading cause of cancer death worldwide, accounting for about 1.3 million deaths annually. However in clinical practice, lung cancer therapies commonly do with chemotherapy, although it is hard because the lung cancer may progress to metastasis stage. The metastasis of lung cancer is highly dependent of expression of matrix me...

متن کامل

Review: the role of coenzymes in clinical enzymology.

Coenzymes participate in many of the enzyme analyses performed in the clinical laboratory. Supplementation of assay systems with optimal levels of coenzymes has recently been recommended as part of efforts to achieve interlaboratory standardization of enzyme measurements. Aspartate aminotransferase and alanine aminotransferase require pyridoxal phosphate for expression of enzyme activity. The r...

متن کامل

Effects of lyophilization of serum on the measurement of apolipoproteins A-I and B.

A common accuracy-based standardization program is indispensable for establishing reference intervals for the clinical use of apolipoproteins. The development and distribution of reference materials and quality-control materials that do not exhibit matrix effects between methods is essential to the standardization process. We examined the suitability of lyophilized material as a common referenc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 39 10  شماره 

صفحات  -

تاریخ انتشار 1993