Coronal Axis Measurement of the Optic Nerve Sheath Diameter.

نویسندگان

  • Giorgio Iaconetta
  • Maddalena De Bernardo
  • Nicola Rosa
چکیده

OBJECTIVES The true optic nerve sheath diameter cutoff value for detecting elevated intracranial pressure is variable. The variability may stem from the technique used to acquire sonographic measurements of the optic nerve sheath diameter as well as sonographic artifacts inherent to the technique. The purpose of this study was to compare the traditional visual axis technique to an infraorbital coronal axis technique for assessing the optic nerve sheath diameter using a high-frequency linear array transducer. METHODS We conducted a cross-sectional study at an academic medical center. Timed optic nerve sheath diameter measurements were obtained on both eyes of healthy adult volunteers with a 10-5-MHz broadband linear array transducer using both traditional visual axis and coronal axis techniques. Optic nerve sheath diameter measurements were obtained by 2 sonologists who graded the difficulty of each technique and were blinded to each other's measurements for each participant. RESULTS A total of 42 volunteers were enrolled, yielding 84 optic nerve sheath diameter measurements. There were no significant differences in the measurements between the techniques on either eye (P = .23 [right]; P = .99 [left]). Additionally, there was no difference in the degree of difficulty obtaining the measurements between the techniques (P = .16). There was a statistically significant difference in the time required to obtain the measurements between the traditional and coronal techniques (P < .05). CONCLUSIONS Infraorbital coronal axis measurements are similar to measurements obtained in the traditional visual axis. The infraorbital coronal axis technique is slightly faster to perform and is not technically challenging.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation of visual axis and coronal axis measurements of the optic nerve sheath diameter.

OBJECTIVE There are several approaches to sonographic imaging and measurement of the optic nerve sheath diameter (ONSD). In this study, we sought to compare visual axis measurements of the optic nerve sheath (ONS) with traditional coronal axis measurements to assess for correlation. METHODS The ONS was visualized in 2 views on both eyes of healthy volunteers using an 8.5-MHz probe. Coronal ax...

متن کامل

Effect of scuba-diving on optic nerve and sheath diameters

  Background :There is not any data available about the effect of high bar pressure condition on intracranial pressure. In this study, the effect of diving on the optic nerve and sheath diameters as non-invasive markers of intracranial pressure has been investigated.   Methods : Twenty professional male divers from twenty one volunteers were chosen for this cross-sectional study. Only one perso...

متن کامل

Brain Trauma Measurement of Optic Nerve Sheath Diameter for the Assessment of Risk of Raised Intracranial Pressure

Raised intracranial pressure (ICP) is associated with poor outcome after brain injury, but is difficult to detect without invasive devices. As a part of the central nervous system, the optic nerve is surrounded by a dural sheath, and the subarachnoid space surrounding the optic nerve is subject to the same pressure changes as the intracranial compartment. Distension of the optic nerve sheath re...

متن کامل

SCIENTIFIC CORRESPONDENCE Measurement of optic nerve sheath diameter by ultrasound: a means of detecting acute raised intracranial pressure in hydrocephalus

Aim: To evaluate the utility of measuring the optic nerve sheath diameter in children with shunted hydrocephalus, suspected of having raised intracranial pressure. Methods: 23 children with shunted hydrocephalus were examined, six had well controlled ICP, 17 however manifested symptoms suggestive of intracranial hypertension. A clinical history was taken from all patients and their parents or c...

متن کامل

Three Dimensional Ultrasonography of the Eye and Measurement of Optical Nerve Sheet Diameter in Dog

Objective-  To determine the possibility of three-dimensional ultrasonography (3DUS) and measurement of optical nerve sheet by this method. Design- Descriptive study. Animals- 10 mixed normal dogs (5males, 5 females), age 1-1.5 year, and weighting 15±5 kg Procedure- 3D ultrasounds of the eyes were evaluated and the normal optical nerves in 3DUS images were measured using Volouson 730 pro....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine

دوره 36 5  شماره 

صفحات  -

تاریخ انتشار 2015