Surface Modification on Acoustic Wave Biosensors for Enhanced Specificity

نویسندگان

  • Onursal Onen
  • Asad A. Ahmad
  • Rasim Guldiken
  • Nathan D. Gallant
چکیده

Changes in mass loading on the surface of acoustic biosensors result in output frequency shifts which provide precise measurements of analytes. Therefore, to detect a particular biomarker, the sensor delay path must be judiciously designed to maximize sensitivity and specificity. B-cell lymphoma 2 protein (Bcl-2) found in urine is under investigation as a biomarker for non-invasive early detection of ovarian cancer. In this study, surface chemistry and biofunctionalization approaches were evaluated for their effectiveness in presenting antibodies for Bcl-2 capture while minimizing non-specific protein adsorption. The optimal combination of sequentially adsorbing protein A/G, anti-Bcl-2 IgG and Pluronic F127 onto a hydrophobic surface provided the greatest signal-to-noise ratio and enabled the reliable detection of Bcl-2 concentrations below that previously identified for early stage ovarian cancer as characterized by a modified ELISA method. Finally, the optimal surface modification was applied to a prototype acoustic device and the frequency shift for a range of Bcl-2 concentration was quantified to demonstrate the effectiveness in surface acoustic wave (SAW)-based detection applications. The surface functionalization approaches demonstrated here to specifically and sensitively detect Bcl-2 in a working ultrasonic MEMS biosensor prototype can easily be modified to detect additional biomarkers and enhance other acoustic biosensors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

TiO2 based surface acoustic wave gas sensor with modified electrode dimensions for enhanced H2 sensing application

The design and optimization of nanostructure-based surface acoustic wave (SAW) gas sensor is analyzed based on TiO2 sensing layer and modified electrode dimensions. The sensitivity of the gas sensor depends upon the type of sensing layer used and active surface area obtained by varying the aspect ratio. The performance of the sensor is observed from 0.1ppm to 100ppm concentration of ...

متن کامل

Biosensors on Surface Acoustic Wave Phononic Band Gap Structures

page 156 Abstract: Already proven in a wide array of industrial applications, surface acoustic wave devices (SAWs) also have been demonstrated to hold substantial potential in the biosensor arena. Currently, SAW resonators coated with a biolayer can distinguish specific biomolecules in both liquid and vapor phases. By incorporating periodic perturbations in the design of SAW delay line, we were...

متن کامل

Surface Generated Acoustic Wave Biosensors for the Detection of Pathogens: A Review

This review presents a deep insight into the Surface Generated Acoustic Wave (SGAW) technology for biosensing applications, based on more than 40 years of technological and scientific developments. In the last 20 years, SGAWs have been attracting the attention of the biochemical scientific community, due to the fact that some of these devices - Shear Horizontal Surface Acoustic Wave (SH-SAW), S...

متن کامل

An interleukin-6 ZnO/SiO(2)/Si surface acoustic wave biosensor.

A novel high sensitivity ZnO/SiO(2)/Si Love mode surface acoustic wave (SAW) biosensor for the detection of interleukin-6 (IL-6), is reported. The biosensors operating at 747.7 MHz and 1.586 GHz were functionalized by immobilizing the monoclonal IL-6 antibody onto the ZnO biosensor surface both through direct surface adsorption and through covalent binding on gluteraldehyde. The morphology of t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2012