Continuous Measurement of Radioactive Isotopes Isolated by an Automatic Analytical Process

نویسندگان

  • J. Colomer
  • G. Metzger
چکیده

INTRODUCTION In an attempt to improve the radioisotope analyses made in our laboratory on the products of fission mixtures, we attempted the replacement of the classical radiochemical methods (separation, then measurement) by automatic methods in which a more sophisticated analytical process is followed by on-line measurement utilizing Cerenkov counting. In the classical methods which are often manual, it is necessary to determine the chemical separation efficiency. This difficult determination is made by different techniques such as gravimetry, absorption spectrometry, etc. and when radiometric measurement is made (f3 or 'y technique) the counting rate so obtained must be corrected and one is forced to consider factors such as detection efficiency, self-absorption and coefficient of geometry, decay scheme and radioactive equilibrium, quenching, etc. In order to avoid these disadvantages we are conducting research, the object of which is the production of a liquid phase radioanalyser in modular form, allowing the continuous analysis of radioisotopes as they become isolated. Figure 1 shows a block diagram of the radioanalyser. The separation unit at uniform concentration is designed around an analytical process, the object of which is to isolate one or more chemical elements. The detection unit which uses Cerenkov detection analyses online the corresponding radioisotope and the measurement is performed versus a standard of activity of the same radioelement, treated under identical experimental conditions. After a short examination of the analytical methods used in the separation unit, we describe the technique employed ii the detection unit and give some examples of its application.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ten Years of Development of Equipment for Measurement of Atmospheric Radioactive Xenon for the Verification of the CTBT

Atmospheric measurement of radioactive xenon isotopes (radioxenon) plays a key role in remote monitoring of nuclear explosions, since it has a high capability to capture radioactive debris for a wide range of explosion scenarios. It is therefore a powerful tool in providing evidence for nuclear testing, and is one of the key components of the verification regime of the Comprehensive Nuclear-Tes...

متن کامل

Removal of cesium through adsorption from aqueous solutions: a systematic review

Cesium radioactive isotopes (134Cs and 137Cs) are dangerous to human health due to their long half-life and high solubility in water. Nuclear experiments, wars, and nuclear plant accidents have been the main sources of Cs release into the environment. In recent years, several methods have been introduced for the elimination of Cs radioactive isotopes from contaminated wate...

متن کامل

Double isotope derivative assay of aldosterone in biological extracts.

The selective measurement of aldosterone in biological fluids has been handicapped by the lack of specific and sensitive assays. Bioassay methods (l-4) have been limited by the variation inherent in animal response. Chemical methods (5-9) require extensive purification procedures to remove contaminants, and are therefore subject to variable recoveries of the steroid. Furthermore, the quantity o...

متن کامل

Fuzzy analytical network process logic for performance measurement system of e-learning centers of universities

This paper proposes an efficient performance measurement system to evaluate the excellence of e-learning centers of universities. The proposed system uses the analytic network process (ANP) as an effective multi-criteria decision making (MCDM) method and its fuzzy mode to respond to uncertainties in judgements. This system also needs a targeted and systematic criteria set which is collected thr...

متن کامل

Spectrofluorometric assay for monoamine-preferring phenol sulfotransferase (SULT1A3).

A continuous and real-time fluorometric assay for monoamine-preferring phenol sulfotransferase (SULT1A3) was developed. The methodology was based on the coupling of SULT1A1 to regenerate 3'-phosphoadenosine-5'-phosphosulfate (PAPS) using 4-methylumbelliferyl sulfate (MUS) as a sulfuryl group donor. The fluorophore product (4-methylumbelliferone, MU) was continuously produced and monitored when ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008