Transcranial color duplex sonography in childhood and adolescence. Age dependence of flow velocities and waveform parameters.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Transcranial color duplex sonographic examinations in children and adolescents without cerebrovascular disease were evaluated retrospectively. Flow velocities and waveform parameters were determined and their side-to-side differences and age dependence analyzed and, finally, compared with analogous data of a previously described group of healthy adults. METHODS With a 2.0-MHz sector transducer of a computed sonographic system, the anterior, middle, and posterior cerebral arteries were examined in 64 children and adolescents between 1.5 and 17.5 years of age. Angle-corrected systolic peak, end-diastolic maximum, time-averaged, and time-averaged maximum velocities, and the resistance, pulsatility, and spectral broadening indexes were determined in all vessels. RESULTS Mean +/- SD values for time-averaged maximum velocity (and time-averaged velocity) were 92.2 +/- 13.0, 79.9 +/- 17.7, and 63.9 +/- 13.6 (55.3 +/- 11.7, 40.4 +/- 10.4, and 34.2 +/- 9.2) cm/s, respectively, in the middle, anterior, and posterior cerebral arteries in children under 10 years of age; values were 83.2 +/- 11.9, 69.4 +/- 13.8, and 55.6 +/- 10.1 (50.8 +/- 9.0, 39.9 +/- 10.5, and 33.1 +/- 6.3) cm/s, respectively, in children 10 years of age and older. Time-averaged maximum velocity decreased significantly with age in all vessels (P < .001). Although time-averaged velocity did not change significantly during childhood and adolescence, a clear decline occurred from adolescence to adulthood (P < .0001 in the middle and posterior cerebral arteries; P < .01 in the anterior cerebral artery). The spectral broadening index decreased significantly from childhood to adolescence in the anterior and posterior cerebral arteries (P < .0001). The resistance and pulsatility indexes remained stable throughout childhood. CONCLUSIONS Transcranial color duplex sonography allows angle-corrected measurements of "true" flow velocities in basal cerebral arteries. Additional determination of time-averaged velocity permits more detailed evaluation of flow characteristics for all age groups. The transcranial color duplex technique may provide deeper insights on normal cerebral perfusion and its disorders.
منابع مشابه
Evaluation of the vertebrobasilar-posterior system by transcranial color duplex sonography in adults.
BACKGROUND AND PURPOSE The transcranial color duplex sonography technique was applied to the vertebrobasilar-posterior system to provide normal data for clinical application. METHODS The intracranial posterior circulation was studied in 49 healthy volunteers (mean +/- SD age, 35 +/- 12 years) by a transcranial and suboccipital approach with a 2.0-MHz sector transducer of a computed sonography...
متن کاملAge dependence of flow velocities in basal cerebral arteries.
Flow velocities in the basal cerebral arteries were studied by transcranial Doppler sonography. A longitudinal study was undertaken on 25 healthy newborn babies during the first 20 days of life, and a cross sectional study was performed on 112 healthy children between 1 day and 18 years of age. A rapid linear increase of flow velocities was found within the first 20 days with higher velocities ...
متن کاملTranscranial Color-Coded Duplex Sonography of Intracranial Veins and Sinuses in Adults
Background and Purpose—Transcranial color-coded duplex sonography (TCCS) of intracranial veins and sinuses in adults is a new, emerging application of ultrasonographic imaging. This study reports a standardized examination protocol for venous TCCS and provides reference data for clinical application. Methods—In 130 healthy volunteers (mean age, 45.9616.9 years; range, 14 to 77 years) the intrac...
متن کاملTranscranial color-coded duplex sonography in unilateral flow-restrictive extracranial carotid artery disease.
PURPOSE To provide transcranial color-coded duplex flow-velocity data for the basal cerebral arteries in patients with unilateral flow-restrictive extracranial carotid artery disease, and to compare these data with the flow velocities obtained in healthy control subjects. METHODS Transcranial color-coded duplex sonography was performed in 78 patients with different patterns of cross flow thro...
متن کاملVertebral Arteries in Healthy Adults
Background and Purpose To noninvasively estimate cerebral blood flow volume, a prospective study of color duplex sonography of the common, external, and internal carotid arteries and vertebral arteries of healthy adults was done. Cerebral blood flow was calculated with the sum of flow volumes in the internal carotid and vertebral arteries of both sides. Methods Using a 7.0-MHz linear transducer...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Stroke
دوره 24 9 شماره
صفحات -
تاریخ انتشار 1993