A compact molecular beam machine.

نویسندگان

  • Paul Jansen
  • David W Chandler
  • Kevin E Strecker
چکیده

We have developed a compact, low cost, modular, crossed molecular beam machine. The new apparatus utilizes several technological advancements in molecular beams valves, ion detection, and vacuum pumping to reduce the size, cost, and complexity of a molecular beam apparatus. We apply these simplifications to construct a linear molecular beam machine as well as a crossed-atomic and molecular beam machine. The new apparatus measures almost 50 cm in length, with a total laboratory footprint less than 0.25 m(2) for the crossed-atomic and molecular beam machine. We demonstrate the performance of the apparatus by measuring the rotational temperature of nitric oxide from three common molecular beam valves and by observing collisional energy transfer in nitric oxide from a collision with argon.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Molecular beams with a tunable velocity.

The merging of molecular beam methods with those of accelerator physics has yielded new tools to manipulate the motion of molecules. Over the last few years, decelerators, lenses, bunchers, traps, and storage rings for neutral molecules have been demonstrated. Molecular beams with a tunable velocity and with a tunable width of the velocity distribution can now be produced, and are expected to b...

متن کامل

A comparison of contralateral breast dose due to breast cancer radiotherapy using two different treatment machines in a radiotherapy center

Background: The radiation dose received by contralateral breast (CLB) is one of the concerns of breast radiotherapy, because it may lead to the induction of secondary breast cancer. The aim of this study was to evaluate the CLB surface dose in the breast treatment in Yazd radiotherapy center. Materials and Methods: The surface dose of CLB was measured using TLD dosimetry in 50 cancer breast pat...

متن کامل

Towards Compact and Fast Neural Machine Translation Using a Combined Method

Neural Machine Translation (NMT) lays intensive burden on computation and memory cost. It is a challenge to deploy NMT models on the devices with limited computation and memory budgets. This paper presents a four stage pipeline to compress model and speed up the decoding for NMT. Our method first introduces a compact architecture based on convolutional encoder and weight shared embeddings. Then...

متن کامل

Commissioning of the world's first compact pencil‐beam scanning proton therapy system

This paper summarizes clinical commissioning of the world's first commercial, clinically utilized installation of a compact, image-guided, pencil-beam scanning, intensity-modulated proton therapy system, the IBA Proteus® ONE, at the Willis-Knighton Cancer Center (WKCC) in Shreveport, LA. The Proteus® ONE is a single-room, compact-gantry system employing a cyclotron-generated proton beam with im...

متن کامل

-heli~ityamplitudesin~+~- L 2& Doublebremsstrahlung*

A compact form for the helicity amplitudes of double bremsstrahlung is presented, utilizing a recently developed method of representing free photon polarizations which produces very compact results. The application as a.polarization monitor in a colliding beam machine such as the SLC is discussed. Submitted to Physical Review D * Work supported by the Department of Energy, contract DE AC03 76SF...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 80 8  شماره 

صفحات  -

تاریخ انتشار 2009