Direct detector device (DDD) cameras have revolutionized single particle electron cryomicroscopy (cryo-EM). In addition to an improved camera detective quantum efficiency, acquisition of DDD movies allows for correction of movement of the specimen, due to both instabilities in the microscope specimen stage and electron beam-induced movement. Unlike specimen stage drift, beam-induced movement is not always homogeneous within an image. Local correlation in the trajectories of nearby particles suggests that beam-induced motion is due to deformation of the ice layer. Algorithms have already been described that can correct movement for large regions of frames and for >1 MDa protein particles. Another algorithm allows individual <1 MDa protein particle trajectories to be estimated, but requires rolling averages to be calculated from frames and fits linear trajectories for particles. Here we describe an algorithm that allows for individual <1 MDa particle images to be aligned without frame averaging or linear trajectories. The algorithm maximizes the overall correlation of the shifted frames with the sum of the shifted frames. The optimum in this single objective function is found efficiently by making use of analytically calculated derivatives of the function. To smooth estimates of particle trajectories, rapid changes in particle positions between frames are penalized in the objective function and weighted averaging of nearby trajectories ensures local correlation in trajectories. This individual particle motion correction, in combination with weighting of Fourier components to account for increasing radiation damage in later frames, can be used to improve 3-D maps from single particle cryo-EM.
منابع مشابه
Movies of ice-embedded particles enhance resolution in electron cryo-microscopy.
Low-dose images obtained by electron cryo-microscopy (cryo-EM) are often affected by blurring caused by sample motion during electron beam exposure, degrading signal especially at high resolution. We show here that we can align frames of movies, recorded with a direct electron detector during beam exposure of rotavirus double-layered particles, thereby greatly reducing image blurring caused by ...
متن کاملBeam-induced motion correction for sub-megadalton cryo-EM particles
In electron cryo-microscopy (cryo-EM), the electron beam that is used for imaging also causes the sample to move. This motion blurs the images and limits the resolution attainable by single-particle analysis. In a previous Research article (Bai et al., 2013) we showed that correcting for this motion by processing movies from fast direct-electron detectors allowed structure determination to near...
متن کاملA Representation Theory Perspective on Simultaneous Alignment and Classification
One of the difficulties in 3D reconstruction of molecules from images in single particle Cryo-Electron Microscopy (Cryo-EM), in addition to high levels of noise and unknown image orientations, is heterogeneity in samples: in many cases, the samples contain a mixture of molecules, or multiple conformations of one molecule. Many algorithms for the reconstruction of molecules from images in hetero...
متن کاملRapid Solution of the Cryo-EM Reconstruction Problem by Frequency Marching
Determining the three-dimensional structure of proteins and protein complexes at atomic resolution is a fundamental task in structural biology. Over the last decade, remarkable progress has been made using “single particle” cryo-electron microscopy (cryo-EM) for this purpose. In cryo-EM, hundreds of thousands of two-dimensional images are obtained of individual copies of the same particle, each...
متن کاملRendering Strategies in Culture-Specific Items: Taboo Expressions in IRIB’s Dubbed Hollywood Movies
Translators face a number of difficulties while translating. Not only translation of cultural elements is of utmost importance in translation studies, but also it is an arduous task for translators, especially in the case of interlingual translation. One of the biggest concerns of audiovisual translators is culture-specific items amongst which taboo expressions are included. This study aimed at...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of structural biology
دوره 192 2 شماره
صفحات -
تاریخ انتشار 2015