Anodic Stripping Voltammetry of Silver Nanoparticles: Aggregation Leads to Incomplete Stripping
نویسندگان
چکیده
The influence of nanoparticle aggregation on anodic stripping voltammetry is reported. Dopamine-capped silver nanoparticles were chosen as a model system, and melamine was used to induce aggregation in the nanoparticles. Through the anodic stripping of the silver nanoparticles that were aggregated to different extents, it was found that the peak area of the oxidative signal corresponding to the stripping of silver to silver(I) ions decreases with increasing aggregation. Aggregation causes incomplete stripping of the silver nanoparticles. Two possible mechanisms of 'partial oxidation' and 'inactivation' of the nanoparticles are proposed to account for this finding. Aggregation effects must be considered when anodic stripping voltammetry is used for nanoparticle detection and quantification. Hence, drop casting, which is known to lead to aggregation, is not encouraged for preparing electrodes for analytical purposes.
منابع مشابه
Successively amplified electrochemical immunoassay based on biocatalytic deposition of silver nanoparticles and silver enhancement.
A successively signal-amplified electrochemical immunoassay has been reported on the basis of the biocatalytic deposition of silver nanoparticles with their subsequent enlargement by nanoparticle-promoted catalytic precipitation of silver from the silver-enhancer solution. The immunoassay was carried out based on a heterogeneous sandwich procedure using polystyrene microwells to immobilize anti...
متن کاملElectrochemical Immunoassay for Cardiac Markers with Magnetic Particles as a Solid Phase and Silver Nanoparticles as an Electroactive Bio-label
− This paper introduces a novel electrochemical detection method for measuring the formation of an immunological complex. The described electrochemical immunoassay consists of several consecutive steps. First the sample is mixed with silver colloid and magnetic particles both previously conjugated to appropriate antibodies. The analyte from the sample binds to both silver and magnetic beads for...
متن کاملAnodic stripping voltammetry determination of Pb, Cd, Zn, and Cu in blood samples of children in some areas of Ibb governorate
Anodic stripping voltammetric determination of Pb, Cd, Zn and Cu in blood samples of 132 children was developed. The children's ages range was between 6 months and 6 years and the samples were collected from different areas of Ibb governorate (Yemen). We used anodic stripping voltammetry for analyzing and determination of cited metals in the blood of all children. Large variation in the results...
متن کاملSimultaneous determination of lead, cadmium, copper and zinc in Infant formula by anodic stripping voltammetry
Determination of trace elements in food is of great importance, as some of them have nutritional significance, whilst others are toxic. Long-term exposure to low levels of toxic metals could be important, especially in relation to children. Differential Pulse Anodic Stripping Voltammetry (DPASV) is applied to simultaneous determination of lead, cadmium, copper and zinc in dry ash infant formula...
متن کاملImproving Reproducibility of Lab-on-a-Chip Sensor with Bismuth Working Electrode for Determining Zn in Serum by Anodic Stripping Voltammetry.
This work reports on the continuing development of a lab-on-a-chip electrochemical sensor for determination of zinc in blood serum using square wave anodic stripping voltammetry. The microscale sensor consists of a three electrode system, including an environmentally friendly bismuth working electrode, an integrated silver/silver chloride reference electrode, and a gold auxiliary electrode. The...