Relating the marginal fit of the castings to the accuracy of the impressions made from laminated hydrocolloid impression technique: a comparative study.
نویسندگان
چکیده
AIM Relating the marginal fit of the castings, to the accuracy of the impression produced using laminated hydrocolloid impression technique, alginate and double-mixed polyvinyl siloxane. Basic objective of the study is to check the feasibility of the use of laminated hydrocolloid impression technique in the fixed partial denture. MATERIALS AND METHODS The precisely machined metal die was designed to simulate standard complete metal crown preparation. The preparation was mounted on cylindrical base of 20 mm length and diameter of 10 mm. Seven impressions were made from the each impression material onto the metal die, and total 21 impressions were obtained from all three impression materials, which were poured by the die stone, and stone die was prepared. Wax patterns were fabricated on stone dies obtained from each impression and then casting was done. All the castings were checked for the marginal fit on metal die after applying a uniform standardized load of 30 pounds using measuring microscope. RESULTS Result revealed that the marginal fit of the castings obtained from group II (laminated hydrocolloid technique) and group III (double-mix polyvinyl polysiloxane) did not show the significant difference between the two of them. Marginal gap of the castings obtained from group I are significantly greater in comparison to the castings obtained from groups II and III (p > 0.01). CONCLUSION Group II (laminated hydrocolloid technique) impression material may be the choice of many clinicians over group III (double-mix polyvinyl polysiloxane) impression material. Group I (alginate impression material), though very cost-effective and easy to handle may not able to produce accurate results. CLINICAL SIGNIFICANCE The study gives overview of the best impression material that can be used clinically. Laminated hydrocolloid technique is the technique of choice.
منابع مشابه
Effects of Water/Powder Ratio of Irreversible Hydrocolloid on Dimensional Stability of Impressions
Background and Aim: Water/powder ratio is effective on some properties of irreversible hydrocolloid impression materials. This study aimed to determine the ef-fects of water/powder ratio of irreversible hydrocolloid impression materials on di-mensional stability of impressions. Materials and Methods: In this in vitro experimental study, a metal model with two abutments as anchoring support for...
متن کاملComparative Analysis of Dimensional Accuracy of Two Types of Silicone Impression Materials: Optosil and Elite-HD
Statement of the Problem: Understanding about impression materials, their properties, uses and manipulation can guide operators towards having more successful restorations. Purpose: The aim of this in vitro study was to compare the accuracy of a condensation silicone impression material, Optosil, and an addition poly siloxane impression material, Elite-HD. Materials and Method: A laboratory mod...
متن کاملDimensional Accuracy of Polyvinyl Siloxane Impression Materials Considering Impression Techniques– A Literature Review
Objectives Impression accuracy is the main determinant of the fit, form and function of prosthetic restorations. Polyvinyl siloxane (PVS) is the material of choice in most clinical situations. The purpose of this paper is to provide an up-to-date review of scientific articles which discuss the dimensional accuracy of PVS impression material using various impression techniques, tray types and sp...
متن کاملمقایسه دقت تکنیکهای مختلف قالبگیری در قالبهای سطح اباتمنت در ایمپلنتهای دندانی با طرح All-on-4
Background and Aims: Passive fit of prosthetic frameworks is a major concern in implant dentistry. Impression technique is one of the several variables that may affect the outcome of dental implants. The purpose of this study was to compare the three dimensional accuracy of direct and indirect abutment level implant impressions of ALL-ON-4 treatment plan.Materials and Methods: A reference acryl...
متن کاملتعیین دقت ثبت ایمپلنت در دو روش تری باز و تری بسته و تعیین ثبت جزئیات سطح دندان حین این قالبگیری
Background and Aims: Accurate recording of implant location is required to achieve passive fit and have the implants without stress concentration. The aim of this in-vitro study was to evaluate the dimensional and angular accuracy of open-tray and closed-tray impression techniques using polyether impression material and also to assess the surface detail reproduction of the tooth while impressio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The journal of contemporary dental practice
دوره 13 2 شماره
صفحات -
تاریخ انتشار 2012