Analysis of Counterfeit Antidiabetic Drugs by UHPLC with the Agilent 1220 Infinity Mobile LC

نویسنده

  • Sonja Schneider
چکیده

Counterfeiting in the pharmaceutical industry has become a serious and underreported problem, particularly in developing countries. This Application Note shows the analysis of antidiabetic drugs of the sulfonylurea class using the Agilent 1220 Infinity Gradient LC system with diode array detector (DAD). Both HPLC and UHPLC methods revealed excellent precision, accuracy and linearity as well as comparable limits of detection and quantification. With retention time and spectral confirmation, chemical antidiabetic substances could be identified and quantified in antidiabetic drugs and dietary supplements. Analysis of Counterfeit Antidiabetic Drugs by UHPLC with the Agilent 1220 Infinity Mobile LC

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

On-site Quality Control of Beer Quantification of Isohumulones and Reduced Isohumulones Using the Agilent 1220 Infinity Mobile LC Solution

This Application Note shows the analysis of isohumulones in different beer samples using the Agilent 1220 Infinity Mobile LC Solution. Direct injection of beer samples and isocratic elution mode enables the user to perform easy on-site measurements in a mobile laboratory without time-consuming sample preparation or method development. With this setup, nonreduced and reduced isohumulone standard...

متن کامل

Comparison of system suitability results according to USP method USP/NF 23 for the analysis of Paracetamol (Acetaminophen) and Aspirin in pain relievers

This analysis used the system suitability test, developed on an Agilent 1200 Series LC system to test whether the Agilent 1220 and Agilent 1260 Infinity LC systems fulfilled the acceptance criteria. The chromatographic conditions of the system suitability test transferred to the Agilent 1260 and Agilent 1220 Infinity LC systems without changes. The results obtained were compared for compliance ...

متن کامل

High-Resolution Analysis of Intact Triglycerides by Reversed Phase HPLC Using the Agilent 1290 Infinity LC UHPLC System

The Agilent 1290 Infinity LC System with ultraviolet/visible (UV/VIS) Diode Array detection (DAD) is used to analyze triglycerides in soybean oil under non-aqueous reversed phase gradient conditions. The Agilent 1290 Infinity LC System was used for the chromatographic separation of the sample on 3.0 and 2.1 mm id C18 columns, of various lengths, with 1.8-μm packing materials prepared in 600 bar...

متن کامل

Analysis of Potential Genotoxic Arylamine and Aminopyridine Impurities in Active Pharmaceutical Ingredients Agilent 1290 Infinity LC system and Agilent 6460A Triple Quadrupole MS system for method development and fast analysis

This Application Note illustrates the possibilities of the Agilent 1290 Infinity LC system and the Agilent 6460A Triple Quadrupole Mass Spectrometer for quantitative analysis of potential genotoxic impurities (PGIs) in active pharmaceutical ingredients (APIs). A generic approach was used to determine arylamine and aminopyridine PGIs in selected APIs. The influence of column length and mobile ph...

متن کامل

Comparing HILIC and RPLC of Morphine Using Agilent ZORBAX RRHD Columns with UHPLC/MS

UHPLC/MS analyses of morphine and 3 of its metabolites (normorphine, morphine3-b-D-glucuronide [M3G], and morphine-6-b-D-glucuronide [M6G]) are used to compare mass spectrometer sensitivity with reversed-phase liquid chromatography (RPLC) and hydrophilic interaction chromatography (HILIC). Two Agilent ZORBAX Rapid Resolution High Definition (RRHD) columns are used in this comparison, an Agilent...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013