Reproducibility of functional MR imaging: preliminary results of prospective multi-institutional study performed by Biomedical Informatics Research Network.

نویسندگان

  • Kelly H Zou
  • Douglas N Greve
  • Meng Wang
  • Steven D Pieper
  • Simon K Warfield
  • Nathan S White
  • Sanjay Manandhar
  • Gregory G Brown
  • Mark G Vangel
  • Ron Kikinis
  • William M Wells
چکیده

PURPOSE To prospectively investigate the factors--including subject, brain hemisphere, study site, field strength, imaging unit vendor, imaging run, and examination visit--affecting the reproducibility of functional magnetic resonance (MR) imaging activations based on a repeated sensory-motor (SM) task. MATERIALS AND METHODS The institutional review boards of all participating sites approved this HIPAA-compliant study. All subjects gave informed consent. Functional MR imaging data were repeatedly acquired from five healthy men aged 20-29 years who performed the same SM task at 10 sites. Five 1.5-T MR imaging units, four 3.0-T units, and one 4.0-T unit were used. The subjects performed bilateral finger tapping on button boxes with a 3-Hz audio cue and a reversing checkerboard. In a block design, 15-second epochs of alternating baseline and tasks yielded 85 acquisitions per run. Functional MR images were acquired with block-design echo-planar or spiral gradient-echo sequences. Brain activation maps standardized in a unit-sphere for the left and right hemispheres of each subject were constructed. Areas under the receiver operating characteristic curve, intraclass correlation coefficients, multiple regression analysis, and paired Student t tests were used for statistical analyses. RESULTS Significant factors were subject (P < .005), k-space (P < .005), and field strength (P = .02) for sensitivity and subject (P = .03) and k-space (P = .05) for specificity. At 1.5-T MR imaging, mean sensitivities ranged from 7% to 32% and mean specificities were higher than 99%. At 3.0 T, mean sensitivities and specificities ranged from 42% to 85% and from 96% to 99%, respectively. At 4.0 T, mean sensitivities and specificities ranged from 41% to 73% and from 95% to 99%, respectively. Mean areas under the receiver operating characteristic curve (+/- their standard errors) were 0.77 +/- 0.05 at 1.5 T, 0.90 +/- 0.09 at 3.0 T, and 0.95 +/- 0.02 at 4.0 T, with significant differences between the 1.5- and 3.0-T examinations and between the 1.5- and 4.0-T examinations (P < .01 for both comparisons). Intraclass correlation coefficients ranged from 0.49 to 0.71. CONCLUSION MR imaging at 3.0- and 4.0-T yielded higher reproducibility across sites and significantly better results than 1.5-T imaging. The effects of subject, k-space, and field strength on examination reproducibility were significant.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Prospective Multi-institutional Study of the Reproducibility of fMRI: A Preliminary Report from the Biomedical Informatics Research Network

Functional magnetic resonance imaging (fMRI) has significantly contributed to understanding both normal and diseased human brains. Variability often exists in the magnitude, spatial distribution, and statistical significance of the resulting fMRI maps due to differences in equipment and other site-specific differences. In addition, because of costly imaging, demanding tasks, and analytical burd...

متن کامل

Function Biomedical Informatics Research Network Recommendations for Prospective Multi-Center Functional Magnetic Resonance Imaging Studies

Corresponding author: Gary H. Glover, Lucas MR Center, 1201 Welch Road, Stanford University Department of Radiology, Stanford, CA 94305, [email protected], PH: (650) 723-7577, FAX: (650) 736-7925. 19Function Biomedical Informatics Research Network (http://www-calit2.nbirn.net/research/function/,https://wiki.birncommunity.org/display/FBIRN/FBIRN+Home) NIH Public Access Author Manuscript J...

متن کامل

Assessment of Reproducibility of Geometric Distortion in MRI using Phantom Measurements

Introduction:  Image  distortion  is  one  of  the  major  problems  of  magnetic  resonance  imaging  (MRI) for use in 3DMRI, velocity MRI, FMRI and radiotherapy treatment planning (RTTP). It is  widely known that the most obvious effect of the inhomogenity of the magnetic fields and the  nonlinearity  of  the  gradient  is  the  Geometric  Distortion  of  MR  tomograms.  In  this  study,  the...

متن کامل

Prostate cancer: sextant localization at MR imaging and MR spectroscopic imaging before prostatectomy--results of ACRIN prospective multi-institutional clinicopathologic study.

PURPOSE To determine the incremental benefit of combined endorectal magnetic resonance (MR) imaging and MR spectroscopic imaging, as compared with endorectal MR imaging alone, for sextant localization of peripheral zone (PZ) prostate cancer. MATERIALS AND METHODS This prospective multicenter study, conducted by the American College of Radiology Imaging Network (ACRIN) from February 2004 to Ju...

متن کامل

Optimized co-registration method of Spinal cord MR Neuroimaging data analysis and application for generating multi-parameter maps

Introduction: The purpose of multimodal and co-registration In MR Neuroimaging is to fuse two or more sets images (T1, T2, fMRI, DTI, pMRI, …) for combining the different information into a composite correlated data set in order to visualization, re-alignment and generating transform to functional Matrix. Multimodal registration and motion correction in spinal cord MR Neuroimag...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiology

دوره 237 3  شماره 

صفحات  -

تاریخ انتشار 2005