Correlations between parameters of aqueous humor dynamics and the influence of central corneal thickness.

نویسندگان

  • Vikas Gulati
  • Deepta A Ghate
  • Carl B Camras
  • Carol B Toris
چکیده

PURPOSE The individual parameters of aqueous humor dynamics may influence each other to maintain intraocular pressure (IOP) homeostasis. Central corneal thickness (CCT) is known to be associated with onset and progression of glaucoma and can potentially influence the individual parameters of aqueous humor dynamics that maintain IOP. This study investigates the correlation between parameters of aqueous humor dynamics and the influence of CCT in healthy volunteers and compares it with the correlations seen in patients with ocular hypertension. METHODS Aqueous humor dynamics (aqueous flow, outflow facility, and uveoscleral outflow), IOP, and pachymetry data from 94 healthy ocular normotensive (ONT) volunteers and 63 ocular hypertensive (OHT) patients was analyzed retrospectively. Linear correlations between individual aqueous humor dynamics parameters and pachymetry were evaluated using scatter plots and the Spearman correlation coefficient where appropriate. RESULTS In both groups, a significant (P < 0.05) negative correlation was found between corneal thickness and aqueous flow (ONT, R(2) = 0.14; OHT, R(2) = 0.10) and between corneal thickness and uveoscleral outflow (ONT and OHT, R(2) = 0.10). A significant (P < 0.05) positive correlation was found between aqueous flow and outflow facility (ONT, R (2) = 0.24; OHT, R(2) = 0.10). In healthy controls, but not OHT patients, a significant (P < 0.001) positive correlation was found between aqueous flow and uveoscleral outflow (R(2) = 0.15). CONCLUSIONS Thicker corneas may be associated with lower aqueous production and lower uveoscleral outflow. The interplay between parameters of aqueous humor dynamics suggests possible autoregulatory mechanisms in the eye. OHT may differ from ONT subjects in their inability to increase the uveoscleral outflow with increases in aqueous inflow.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Oxidative Stress Levels in Aqueous Humor from High Myopic Patients.

PURPOSE To compare oxidative stress status in the aqueous humor of highly myopic eyes and control eyes. METHODS Aqueous humor samples were collected from 15 highly myopic eyes (high myopia group) and 23 cataractous eyes (control group) during cataract surgery. Central corneal thickness, corneal endothelial cell density, hexagonality of corneal endothelial cells, and cell area of corneal endot...

متن کامل

Characterization of ocular biometrics and aqueous humor dynamics in primary angle closure suspects

Detailed characterizations of ocular biometrics and parameters of aqueous humor dynamics are lacking in primary angle closure suspect (PACS) patients. This study aims to characterize these parameters and compare them with age-matched healthy volunteers.Elderly healthy volunteers (60.6 ± 7.2 years of age, mean ± SD, n = 28) and PACS patients (64.1 ± 11.6 years, n = 30) completed the study. Param...

متن کامل

Comparison of Central Corneal Thickness Measured through Pentacam, OCTCasia2, and Orbscan IIz in Normal Individuals

Purpose: To compare the central corneal thickness measured through Pentacam, OCTCasia2, and Orbscan IIz in normal individuals. Methods: In this cross sectional comparative study, the researcher investigated the eyes of 70 normal candidates (140 eyes) with the mean age of 31.42 ± 7.70, referring to Dr. Sedaghat eye clinic for refractive surgery. For each person, Central Corneal Thickness (CCT) w...

متن کامل

Aqueous humor dynamics during the day and night in juvenile and adult rabbits.

PURPOSE To determine the day and night differences in intraocular pressure (IOP), aqueous flow, outflow facility, uveoscleral outflow, and central corneal thickness (CCT) in juvenile and adult rabbits. METHODS Studies were performed on twelve 3-month-old and ten 12-month-old male New Zealand White rabbits. Daytime measurements were made between 9 AM (3 hours after lights on) and 3 PM, and nig...

متن کامل

Impact of the environment on the mammalian corneal epithelium.

PURPOSE To evaluate whether the content of ascorbic acid in the corneal epithelium and aqueous humor reflects seasonal fluctuations in parallel with environmental changes. METHODS Reindeer, cattle, rabbits, and humans were examined, to cover a broad spectrum of overlapping habitats. Ascorbic acid was determined by high-performance liquid chromatography. The thickness of the corneal epithelium...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 52 2  شماره 

صفحات  -

تاریخ انتشار 2011