Predicting physical activity energy expenditure in wheelchair users with a multisensor device
نویسندگان
چکیده
AIM To assess the error in predicting physical activity energy expenditure (PAEE), using a multisensor device in wheelchair users, and to examine the efficacy of using an individual heart rate calibration (IC) method. METHODS 15 manual wheelchair users (36±10 years, 72±11 kg) completed 10 activities: resting, folding clothes, wheelchair propulsion on a 1% gradient (3456 and 7 km/h) and propulsion at 4 km/h (with an additional 8% of body mass, 2% and 3% gradient) on a motorised wheelchair treadmill. Criterion PAEE was measured using a computerised indirect calorimetry system. Participants wore a combined accelerometer and heart rate monitor (Actiheart). They also performed an incremental arm crank ergometry test to exhaustion which permitted retrospective individual calibration of the Actiheart for the activity protocol. Linear regression analysis was conducted between criterion (indirect calorimetry) and estimated PAEE from the Actiheart using the manufacturer's proprietary algorithms (group calibration, GC) or IC. Bland-Altman plots were used and mean absolute error was calculated to assess the agreement between criterion values and estimated PAEE. RESULTS Predicted PAEE was significantly (p<0.01) correlated with criterion PAEE (GC, r=0.76 and IC, r=0.95). The absolute bias ±95% limits of agreement were 0.51±3.75 and -0.22±0.96 kcal/min for GC and IC, respectively. Mean absolute errors across the activity protocol were 51.4±38.9% using GC and 16.8±15.8% using IC. SUMMARY PAEE can be accurately and precisely estimated using a combined accelerometer and heart rate monitor device, with integration of an IC. Interindividual variance in cardiovascular function and response to exercise is high in this population. Therefore, in manual wheelchair users, we advocate the use of an IC when using the Actiheart to predict PAEE.
منابع مشابه
A compendium of energy costs of physical activities for individuals who use manual wheelchairs.
The purpose of this study was to develop a compendium of wheelchair-related physical activities. To accomplish this, we conducted a systematic review of the published energy costs of activities performed by individuals who use wheelchairs. A total of 266 studies were identified by a literature search using relevant keywords. Inclusion criteria were studies utilizing individuals who routinely us...
متن کاملMeasuring energy expenditure after stroke: validation of a portable device.
BACKGROUND AND PURPOSE Current means of assessing physical activity and energy expenditure have restrictions in stroke, limiting our understanding of its role in therapeutic management. This study validates a portable multisensor array for measuring free-living total energy expenditure compared with a gold standard method (doubly labeled water) in individuals with stroke. METHODS Daily energy...
متن کاملMeasuring Heart Rate in Manual Wheelchair Users during Exercise and Free-living Activity with the latest Fitbit Surge Monitor
Researchers have been validating the off-the-shelf activity monitors and customizing devices to help manual wheelchair users (MWUs) objectively monitor their daily physical activity (PA), a critical factor in optimizing health and function. Some of these devices track heart rate (HR) and use it to predict energy expenditure (EE). The validity of these monitors in predicting EE depends on the ac...
متن کاملMeasurement of Physical Activity and Energy Expenditure in Wheelchair Users: Methods, Considerations and Future Directions
Accurately measuring physical activity and energy expenditure in persons with chronic physical disabilities who use wheelchairs is a considerable and ongoing challenge. Quantifying various free-living lifestyle behaviours in this group is at present restricted by our understanding of appropriate measurement tools and analytical techniques. This review provides a detailed evaluation of the curre...
متن کاملInfluence of Accelerometer Type and Placement on Physical Activity Energy Expenditure Prediction in Manual Wheelchair Users
PURPOSE To assess the validity of two accelerometer devices, at two different anatomical locations, for the prediction of physical activity energy expenditure (PAEE) in manual wheelchair users (MWUs). METHODS Seventeen MWUs (36 ± 10 yrs, 72 ± 11 kg) completed ten activities; resting, folding clothes, propulsion on a 1% gradient (3,4,5,6 and 7 km·hr-1) and propulsion at 4km·hr-1 (with an addit...
متن کامل